Abstract
The first application of tunable, coherent VUV radiation to the measurement of absorption lineshapes in a dense (ne=1024-1025 m-3) plasma is reported. The coherent VUV radiation was produced by frequency tripling the output of a powerful dye laser at the Rutherford Appleton Laboratory UV Radiation Facility. The VUV radiation (tunable between 1203 and 1236 AA) was used to obtain absorption profiles of hydrogen Lyman- alpha in the cool, (Te=2-2.5 eV), near non-Debye Z-pinch plasma. The absorption profiles indicated a possible red wing asymmetry observed previously in emission on the same device.