Baseline Correction Method Using an Orthogonal Basis for Gas Chromatography/Mass Spectrometry Data
Authors:
- 8 August 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (19) , 7464-7471
Abstract
A baseline correction method that uses basis set projection to estimate spectral backgrounds has been developed and applied to gas chromatography/mass spectrometry (GC/MS) data. An orthogonal basis was constructed using singular value decomposition (SVD) for each GC/MS two-way data object from a set of baseline mass spectra. A novel aspect of this baseline correction method is the regularization parameter that prevents overfitting that may produce negative peaks in the corrected mass spectra or ion chromatograms. The number of components in the basis, the regularization parameter, and the mass spectral range from which the spectra were sampled to construct the basis were optimized so that the projected difference resolution (PDR) or signal-to-noise ratio (SNR) was maximized. PDR is a metric similar to chromatographic resolution that indicates the separation of classes in a multivariate data space. This new baseline correction method was evaluated with two synthetic data sets and a real GC/MS data set. The prediction accuracies obtained by using the fuzzy rule-building expert system (FuRES) and partial least-squares–discriminant analysis (PLS-DA) as classifiers were compared and validated through bootstrapped Latin partition (BLP) between data before and after baseline correction. The results indicate that baseline correction of the two-way GC/MS data using the proposed methods resulted in a significant increase in average PDR values and prediction accuracies.Keywords
This publication has 31 references indexed in Scilit:
- Classification of Jet Fuel Properties by Near-Infrared Spectroscopy Using Fuzzy Rule-Building Expert Systems and Support Vector MachinesApplied Spectroscopy, 2010
- A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometersAnalytica Chimica Acta, 2008
- Resolving the sign ambiguity in the singular value decompositionJournal of Chemometrics, 2008
- Bootstrap classification and point-based feature selection from age-staged mouse cerebellum tissues of matrix assisted laser desorption/ionization mass spectra using a fuzzy rule-building expert systemAnalytica Chimica Acta, 2007
- Fuzzy Rule-Building Expert System Classification of Fuel Using Solid-Phase Microextraction Two-Way Gas Chromatography Differential Mobility Spectrometric DataAnalytical Chemistry, 2007
- Statistical validation of classification and calibration models using bootstrapped Latin partitionsTrAC Trends in Analytical Chemistry, 2006
- Partial least-squares regression: a tutorialAnalytica Chimica Acta, 1986
- prediction of wine quality and geographic origin from chemical measurements by parital least-squares regression modelingAnalytica Chimica Acta, 1984
- Quantitative gas chromatography/Fourier transform infrared spectrometry with integrated gram-Schmidt reconstruction intensitiesAnalytical Chemistry, 1982
- Comparison of methods for reconstruction of gas chromatograms from interferometric gas chromatography/infrared spectrometry dataAnalytical Chemistry, 1981