The influence of nonlinear fields on miniature hydrophone calibration using the planar scanning technique
Author:
- 1 March 1988
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 35 (2) , 162-167
Abstract
Miniature polyvinylidene fluoride (PVDF) hydrophones used in determining the power and intensity output of ultrasonic fields, including those radiated from diagnostic ultrasound equipment, were calibrated under a variety of field conditions using the planar scanning technique. A diagnostic B-scan piston-type transducer was used as a source, and the output intensity (spatial-peak pulse-average, or SPPA) was varied from 2 to 30 W/cm/sup 2/ while the total power was kept constant. The higher-intensity waveforms were significantly nonlinear in the focal region of the source. When the lateral beam profiles of the source (as measured by the hydrophone to be calibrated) were determined by positive-peak-detecting the ultrasonic pulse, the calibrated pressure sensitivity of the hydrophone systematically decreased as the field became progressively more nonlinear. When the beam profiles were measured using the pulse intensity integral, no systematic dependence of the calibration on field linearity was noted. These results imply that measured values of power and intensity of ultrasound diagnostic equipment may be dependent on the methodology utilized to map the lateral beam profiles of the transducer being measured, and the extent of nonlinear effects in the field under characterization.<>Keywords
This publication has 10 references indexed in Scilit:
- A discussion of procedures for ultrasonic intensity and power calculations from miniature hydrophone measurementsUltrasound in Medicine & Biology, 1985
- An Ultrasonic Absolute Power Transfer StandardJournal of Research of the National Bureau of Standards, 1984
- Finite amplitude distortion of the pulsed fields used in diagnostic ultrasoundUltrasound in Medicine & Biology, 1984
- Acoustic shock generation by ultrasonic imaging equipmentBritish Journal of Radiology, 1984
- Calibration of miniature ultrasonic receivers using a planar scanning techniqueThe Journal of the Acoustical Society of America, 1982
- A comparison of two calibration methods for ultrasonic hydrophonesUltrasound in Medicine & Biology, 1982
- Simplified technique for the calibration and use of a miniature hydrophone in intensity measurements of pulsed ultrasound fieldsThe Journal of the Acoustical Society of America, 1981
- Miniature piezoelectric polymer ultrasonic hydrophone probesUltrasonics, 1981
- Calibration and Performance Evaluation of Miniature Ultrasonic Hydrophones Using Time Delay Spectrometry1981
- Prediction of nonlinear acoustic effects at biomedical frequencies and intensitiesUltrasound in Medicine & Biology, 1980