Assessment of Hemodialysis Adequacy by Ionic Dialysance: Comparison to Standard Method of Urea Removal
- 1 January 2005
- journal article
- research article
- Published by Taylor & Francis in Renal Failure
- Vol. 27 (5) , 601-604
Abstract
Background. The hemodialysis adequacy is one of the most important issues influencing the survival of patients on maintenance hemodialysis (HD). Assessment of measuring the delivered dialysis dose using clearance × time/volume (Kt/V) index requires multiple blood sampling. New methods for assessment of dialysis dose based on ionic dialysance (ID) have been suggested. Online conductivity monitoring (using sodium flux as a surrogate for urea) allows the repeated noninvasive measurement of Kt/V on each HD treatment. In this study we have compared this method with the standard method of estimating Kt/V. Methods. We studied 24 established HD patients over a 4 week time period. Patients were dialyzed using Fresenius 4008S dialysis monitors, equipped with modules to measure ID. Data were manually collected and analyzed using the appropriate statistical software. Urea removal (UR) was measured once a week by a two-pool calculation, estimating an eKt/V. Results. The Kt/V measured by ID highly correlated with the one derived from the measurement of the UR (r = 0.8959, p< 0.0001). The ID underestimated UR by the mean of 6%. The ID varied greatly within individual patients with a median of 1.29 ± 0.22. If the eKt/V ≥ 1.2 is considered adequate, 33% of the patients would have been inadequately dialyzed. The mean HD duration to achieve an adequate dialysis was 4 hours and 47 minutes with high interpatient variability. Conclusion. The ID seems to be an easily obtained measure of the delivered dialysis dose, correlating well with standard UR method. Substantial individual variations imply that repeated measures (ideally for all treatments) are necessary to obtain a real answer to the mean treatment dose being delivered to the patients.Keywords
This publication has 10 references indexed in Scilit:
- Haemodialysis with on-line monitoring equipment: tools or toys?Nephrology Dialysis Transplantation, 2005
- Assessment of haemodialysis adequacy by ionic dialysance: intra-patient variability of delivered treatmentNephrology Dialysis Transplantation, 2003
- Effect of Dialysis Dose and Membrane Flux in Maintenance HemodialysisNew England Journal of Medicine, 2002
- Dialysis Dose and Body Mass Index Are Strongly Associated with Survival in Hemodialysis PatientsJournal of the American Society of Nephrology, 2002
- Accuracy and safety of online clearance monitoring based on conductivity variationNephrology Dialysis Transplantation, 2001
- Continuous quality improvement: DOQI becomes K/DOQI and is updatedAmerican Journal of Kidney Diseases, 2001
- Recent developments in conductivity monitoring of haemodialysis sessionNephrology Dialysis Transplantation, 1999
- Lessons from the hemodialysis (HEMO) Study: An improved measure of the actual hemodialysis doseAmerican Journal of Kidney Diseases, 1999
- The dose of hemodialysis and patient mortalityKidney International, 1996
- A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)Kidney International, 1985