Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffrattive IOL (ReSTOR) and Three Monofocal IOLs
Authors:
- Maria Regina ChalitaMCMaria Regina Chalita
- Carlos Eduardo B SouzaCSCarlos Eduardo B Souza
- Eduardo S SorianoESEduardo S Soriano
- Lincoln L FreitasLFLincoln L Freitas
- Cristina MuccioliCMCristina Muccioli
- Rubens BelfortRBRubens Belfort
- 1 November 2005
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 21 (6) , S808-S812
Abstract
PURPOSE: To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS: A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alcon Acrysof MA30AC [20 eyes], Alcon Acrysof SA60AT [20 eyes], and Mediphacos Acqua IOL [15 eyes]) was carried out. All eyes were targeted for emmetropia. Complete ophtha lmological examination, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), contrast sensitivity (Pelli- Robson chart), and wavefront analysis, was performed 2 months postoperatively. RESULTS: All eyes in all groups had BSCVA ≥20/32 postoperatively. Mean total aberration root-meansquare (RMS) values were: 0.72?0.25 µm (ReSTOR), 0.94?0.26 µm (MA30), 0.84?0.23 µm) (SA60), and 2. 04 ?0.77 µm (Acqua). Mean higher order aberration values were: 0.35?0.15 µm (ReSTOR), 0.41 ± 0.12 µm (MA30), 0.43±0.13 µm) (SA60), and 0.85±0.50 µm) (Acqua). The Acqua IOL showed statistically significant more total and higher order aberrations when compared with the other IOLs (P<.05). The ReSTOR IOL showed statistically significant less induction of spherical aberration when compared to the monofocal IOLs (P<.05). Mean contrast sensitivity values were: 1.64 ?0.08 (ReSTOR), 1.72?0.08 (MA30), 1.70?0.07 (SA60), and 1.65?0.11 (Acqua). CONCLUSIONS: Different types of IOLs resulted in measurably different postoperative higher order aberration patterns. The multifocal apodized diffractive IOL (ReSTOR) induced significantly less spherical aberration compared to the monofocal IOLs. Contrast sensitivity revealed better values with MA30 and SA60 IOLs when compared to ReSTOR. The integration of wavefront technology in evaluating Pseudophakie patients represents a step towards better understanding and analyzing postoperative visual quality. [J Refract Surg. 2005;21: S808-S812.]Keywords
This publication has 20 references indexed in Scilit:
- Higher-order aberrations of lenticular opacitiesJournal of Cataract & Refractive Surgery, 2004
- Age-related changes in corneal and ocular higher-order wavefront aberrationsAmerican Journal of Ophthalmology, 2004
- Wavefront corrections of intraocular lensesOphthalmology Clinics of North America, 2004
- High-order aberrations with Hydroview H60M and AcrySof MA30BA intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- High-order aberrations in pseudophakia with different intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focusJournal of Cataract & Refractive Surgery, 2003
- Impact of a modified optic design on visual function: Clinical comparative studyJournal of Cataract & Refractive Surgery, 2003
- Distance and near contrast sensitivity function after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2003
- Normal values for the Pelli-Robson contrast sensitivity testJournal of Cataract & Refractive Surgery, 2001
- Comparison of Acuity, Contrast Sensitivity, and Disability Glare Before and After Cataract SurgeryArchives of Ophthalmology (1950), 1993