Development of a rapid point-of-care patient reported outcome measure for cataract surgery in India
Authors:
- Joshua R. EhrlichJEJoshua R. Ehrlich
- Charlie FrankCFCharlie Frank
- Josiah SmileyJSJosiah Smiley
- Hong-Gam LeHLHong-Gam Le
- Sanil JosephSJSanil Joseph
- Stephen G. SchillingSSStephen G. Schilling
- Brian C. StaggBSBrian C. Stagg
- Joshua D. SteinJSJoshua D. Stein
- R. D. RavindranRRR. D. Ravindran
- Aravind HaripriyaAHAravind Haripriya
Open Access
- 30 January 2018
- journal article
- research article
- Published by Springer Nature in Health and Quality of Life Outcomes
- Vol. 16 (1) , 25
Abstract
For patient undergoing cataract surgery in India, existing patient-reported outcome (PRO) measures are either not culturally relevant, have not been adequately validated, or are too long to be used in a busy clinical setting. We sought to develop and validate a brief and culturally relevant point-of-care PRO measure to address this need. Twelve items from the Indian Visual Functioning Questionnaire (IND-VFQ) were selected based on preliminary data. Patients 18 years and older were prospectively recruited at Aravind Eye Care System in Madurai, India. Clinical and sociodemographic data were collected and the 12-item short-form IND-VFQ (SF-IND-VFQ) was administered pre- and post-operatively to 225 patients; Factor analysis and Rasch modeling was performed to assess its psychometric properties. One item that did not fit a unidimensional scale and had poor fit with the Rasch model was eliminated from the questionnaire. The remaining 11 items represented a single construct (no residual correlations> 0.1) and were largely unaffected by differential item functioning. Five items had disordered thresholds resolved by collapsing the response scale from four to three categories. The survey had adequate reliability (0.80) and good construct (infit range, 0.77–1.29; outfit range, 0.56–1.30) and content (item separation index, 5.87 logits) validity. Measurement precision was fair (person separation index, 1.97). There was evidence that items were not optimally targeted to patients’ visual ability (preoperatively, − 1.92 logits; overall, − 3.41 logits), though the survey measured a very large effect (Cohen’s d 1.80). In a subset of patients, the average time to complete the questionnaire was 2 min 6.3 s. The SF-IND-VFQ is a valid, reliable, sensitive, and rapidly administered point-of-care PRO measure to assess changes in visual functioning in patients undergoing cataract surgery in India.Keywords
Funding Information
- Heed Ophthalmic Foundation (n/a)
- Summer Biomedical Research Program, University of Michigan (n/a, n/a)
- National Eye Institute (K23EY027848)
This publication has 24 references indexed in Scilit:
- Patient-Reported Outcomes — Harnessing Patients’ Voices to Improve Clinical CareThe New England journal of medicine, 2017
- The Role of Patient Reported Outcomes (PROs) in Healthcare Policy MakingSystematic Reviews in Pharmacy, 2016
- Cost-effectiveness analysis should continually assess competing health care options especially in high volume environments like cataract surgeryIndian Journal Of Ophthalmology, 2015
- The Impact of Successful Cataract Surgery on Quality of Life, Household Income and Social Status in South IndiaPLOS ONE, 2012
- Remediating serious flaws in the National Eye Institute Visual Function QuestionnaireJournal of Cataract & Refractive Surgery, 2010
- The outcome of cataract surgery measured with the Catquest-9SFActa Ophthalmologica, 2009
- Impact of Impaired Vision and Eye Disease on Quality of Life in Andhra PradeshInvestigative Ophthalmology & Visual Science, 2006
- The development of the Indian vision function questionnaire: field testing and psychometric evaluationBritish Journal of Ophthalmology, 2005
- Prediction of Visual Function After Cataract SurgeryArchives of Ophthalmology (1950), 1995
- The VF-14Archives of Ophthalmology (1950), 1994