Comparison of Hemoglobin A1c with fasting and 2-h plasma glucose tests for diagnosis of diabetes and prediabetes among high-risk South Indians
Open Access
- 1 January 2018
- journal article
- research article
- Published by Medknow in Indian Journal of Endocrinology and Metabolism
- Vol. 22 (1) , 50-56
Abstract
Background: Glycosylated hemoglobin (HbA1c) has not been evaluated extensively for diabetes and prediabetes diagnosis and short-term variability of fasting plasma glucose (FPG), 2-h PG post-75 g glucose load (2 hPG) and HbA1c has not been studied among Indians. Objectives: The study aimed to compare the sensitivity of HbA1c, FPG and 2 hPG for diabetes and prediabetes diagnosis as per the American Diabetes Association criteria, assess short-term variability of three tests and determine optimal HbA1c cutoffs for diabetes and prediabetes diagnosis among high-risk south Indians. Methods: This diagnostic accuracy study, conducted at a tertiary care teaching hospital located in South India, enrolled 332 adults at high risk for diabetes and subjected them to testing (FPG, 2 hPG, and HbA1c) twice at 2–3 weeks interval. Sensitivity of three tests for diagnosing diabetes and prediabetes was determined based on the final diagnosis of normoglycemia/prediabetes/diabetes made with six test results for each participant. Optimal HbA1c cutoffs for diabetes and prediabetes were determined based on the final diagnosis of glycemic status made with four test results of FPG and 2 hPG. Results: FPG, 2 hPG, and HbA1c, at American Diabetes Association recommended values, had sensitivity of 84.4%, 97%, and 93.8% respectively for diabetes diagnosis. HbA1c had lowest short-term variability (CVw = 1.6%). Receiver operating characteristic curve plotted with mean (of two values) HbA1c for each participant showed optimal HbA1c cutoffs of 6.5% for diabetes (area under curve [AUC] =0.990, sensitivity = 95.8%, specificity = 96.2%, accuracy = 95.2%) and 5.9% for prediabetes (AUC = 0.893, sensitivity = 84.3%, specificity = 80%, accuracy = 75.6%) diagnosis respectively. HbA1c <5.6% had 100% negative predictive value to exclude prediabetes/diabetes. Conclusions: HbA1c ≥6.5% is a convenient and reliable alternative to plasma glucose tests to diagnose diabetes among high-risk South Indians. HbA1c ≥5.9% is optimal for prediabetes diagnosis and value <5.6% excludes prediabetes/diabetes.Keywords
This publication has 26 references indexed in Scilit:
- Accuracy of glycated haemoglobin in screening for pre‐diabetes in Asian Indians—a community survey: the Chandigarh Urban Diabetes Study (CUDS)Diabetic Medicine, 2012
- IDF Diabetes Atlas: Global estimates of the prevalence of diabetes for 2011 and 2030Diabetes Research and Clinical Practice, 2011
- HbA1c values for defining diabetes and impaired fasting glucose in Asian IndiansPrimary Care Diabetes, 2011
- The Pros and Cons of Diagnosing Diabetes With A1CDiabetes Care, 2011
- Standards of Medical Care in Diabetes—2010Diabetes Care, 2010
- Performance of an A1C and Fasting Capillary Blood Glucose Test for Screening Newly Diagnosed Diabetes and Pre-Diabetes Defined by an Oral Glucose Tolerance Test in Qingdao, ChinaDiabetes Care, 2009
- A1C Cut Points to Define Various Glucose Intolerance Groups in Asian IndiansDiabetes Care, 2009
- Comparison of A1C and Fasting Glucose Criteria to Diagnose Diabetes Among U.S. AdultsDiabetes Care, 2009
- Short-term Variability in Measures of Glycemia and Implications for the Classification of DiabetesArchives of internal medicine (1960), 2007
- Derivation and validation of diabetes risk score for urban Asian IndiansDiabetes Research and Clinical Practice, 2005