Volumetric Single-Beat Coronary Computed Tomography Angiography
- 1 January 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 40 (5) , 763-772
Abstract
Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m2), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m2 and BMI greater than 30 kg/m2. Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m2 or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m2 (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m2 or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m2 (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m2 or less, and BMI greater than 30 kg/m2.Keywords
This publication has 29 references indexed in Scilit:
- The PROMISE trial: An inside perspectiveJournal of Cardiovascular Computed Tomography, 2015
- CT coronary angiography in patients with suspected angina due to coronary heart disease (SCOT-HEART): an open-label, parallel-group, multicentre trialThe Lancet, 2015
- The diagnostic and prognostic value of coronary CT angiography in asymptomatic high-risk patients: a cohort studyOpen Heart, 2014
- PROspective Multicenter Imaging Study for Evaluation of chest pain: Rationale and design of the PROMISE trialAmerican Heart Journal, 2014
- Diagnostic Accuracy and Radiation Dose of CT Coronary Angiography in Atrial Fibrillation: Systematic Review and Meta-AnalysisRadiology, 2013
- Assessment of image quality and radiation dose of prospectively ECG-triggered adaptive dual-source coronary computed tomography angiography (cCTA) with arrhythmia rejection algorithm in systole versus diastole: a retrospective cohort studyThe International Journal of Cardiovascular Imaging, 2013
- Prevalence of Obesity and Trends in the Distribution of Body Mass Index Among US Adults, 1999-2010JAMA, 2012
- The Obese Emergency Patient: Imaging Challenges and SolutionsRadioGraphics, 2011
- ACCF/AHA Clinical Competence Statement on Cardiac Imaging With Computed Tomography and Magnetic ResonanceCirculation, 2005
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975