Design and construction of a Maxwell-type induction coil for magnetic nanoparticle hyperthermia
Authors:
Open Access
- 1 January 2020
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 37 (1) , 1-14
Abstract
Purpose: We describe a modified Helmholtz induction coil, or Maxwell coil, that generates alternating magnetic fields (AMF) having field uniformity (≤10%) within a = 3000 cm3 volume of interest for magnetic hyperthermia research. Materials and methods: Two-dimensional finite element analysis (2D-FEA) was used for electromagnetic design of the induction coil set and to develop specifications for the required matching network. The matching network and induction coil set were fabricated using best available practices and connected to a 120 kW industrial induction heating power supply. System performance was evaluated by magnetic field mapping with a magnetic field probe, and tests were performed using gel phantoms. Results: Tests verified that the system generated a target peak AMF amplitude along the coil axis of ∼35 kA/m (peak) at a frequency of 150 ± 10 kHz while maintaining field uniformity to >90% of peak for a volume of ∼3000 cm3. Conclusions: The induction coil apparatus comprising three independent loops, i.e., Maxwell-type improves upon the performance of simple solenoid and Helmholtz coils by providing homogeneous flux density fields within a large volume while minimizing demands on power and stray fields. Experiments with gel phantoms and analytical calculations show that future translational research efforts should be devoted to developing strategies to reduce the impact of nonspecific tissue heating from eddy currents; and, that an inductor producing a homogeneous field has significant clinical potential for deep-tissue magnetic fluid hyperthermia.Keywords
Funding Information
- National Cancer Institute (U54CA151838, P50CA062924, R21CA161626, 5R01CA194574-02)
This publication has 50 references indexed in Scilit:
- Method to reduce non-specific tissue heating of small animals in solenoid coilsInternational Journal of Hyperthermia, 2013
- Efficacy and safety of intratumoral thermotherapy using magnetic iron-oxide nanoparticles combined with external beam radiotherapy on patients with recurrent glioblastoma multiformeJournal of Neuro-Oncology, 2010
- Nearly complete regression of tumors via collective behavior of magnetic nanoparticles in hyperthermiaNanotechnology, 2009
- Transient temperature rise in a mouse due to low-frequency regional hyperthermiaPhysics in Medicine & Biology, 2006
- On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRIIEEE Transactions on Biomedical Engineering, 2003
- The Induction of Hyperthermia in Rabbit Liver by means of Duplex Stainless Steel ThermoseedsKorean Journal of Radiology, 2002
- Optimal design procedure for a practical induction heating cookerIEEE Transactions on Magnetics, 2000
- Optimization of the Loney's solenoid through quasi-analytical strategies: a benchmark problem reconsideredIEEE Transactions on Magnetics, 1997
- Energy considerations in the magnetic (eddy-current) stimulation of tissuesIEEE Transactions on Magnetics, 1991
- Evaluation of a semi-cylindrical solenoid as an applicator for radio-frequency hyperthermiaIEEE Transactions on Biomedical Engineering, 1989