Subcrestal placement of two‐part implants
Authors:
- 5 February 2009
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 20 (3) , 226-231
Abstract
The aim of the present experiment was to study the healing around two-part implants that were placed in a subcrestal position. Five mongrel dogs, about 2 years old, were included. The mandibular premolars and the first, second and third maxillary premolars were extracted. Three months later two test and two control implants (OsseoSpeed, 3.5 mm x 8 mm) were placed in one side of the mandible. The implants were placed in such a way that the implant margin was located 2 mm apical to the bone crest. In the test implants, the surface modification extended to the implant margin and, thus, included the shoulder part of the implant. Regular abutments with a turned surface (Zebra) were connected to the control implants, while experimental abutments with a modified surface (TiOblast) were connected to the test implants. A plaque control program that included cleaning of implants and teeth every second day was initiated. Four months later the dogs were euthanized and biopsies were obtained and prepared for histological analysis. The marginal bone level at the test implants was identified in a more coronal position than that at the control implants. In 40% of the test implants, the bone-to-implant contact extended coronal of the abutment/fixture (A/F) border, i.e. in contact with the abutment part of the implant. The connective tissue portion of the peri-implant mucosa that was facing the test abutments contained a higher density of collagen and a smaller proportion of fibroblasts than that at the control sites. It is suggested that osseointegration may occur coronal to the A/F interface of two-part implants. Such a result, however, appears to depend on the surface characteristics of the implant components.Keywords
This publication has 25 references indexed in Scilit:
- Morphogenesis of the peri‐implant mucosa: an experimental study in dogsClinical Oral Implants Research, 2007
- Bone reactions to longstanding functional load at implants: an experimental study in dogsJournal of Clinical Periodontology, 2005
- Early bone formation adjacent to rough and turned endosseous implant surfacesClinical Oral Implants Research, 2004
- Tissue Reactions to Abutment Shift: An Experimental Study in DogsClinical Implant Dentistry and Related Research, 2003
- De novo alveolar bone formation adjacent to endosseous implantsClinical Oral Implants Research, 2003
- The mucosal attachment to titanium implants with different surface characteristics: an experimental study in dogsJournal of Clinical Periodontology, 2002
- Peri‐implant tissues at submerged and non‐submerged titanium implantsJournal of Clinical Periodontology, 1999
- The mucosal barrier following abutment dis/reconnectionJournal of Clinical Periodontology, 1997
- Dimension of the periimplant mucosaJournal of Clinical Periodontology, 1996
- The peri‐implant hard and soft tissues at different implant systems. A comparative study in the dog.Clinical Oral Implants Research, 1996