Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis
Authors:
Open Access
- 11 February 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0148964
Abstract
Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest. The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal. A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k−50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz−2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB. The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal-to-noise quality of 10 dB if the high-pass 3 dB frequency is suitably selected.Keywords
This publication has 39 references indexed in Scilit:
- Studies in RF Power Communication, SAR, and Temperature Elevation in Wireless Implantable Neural InterfacesPLOS ONE, 2013
- Learning an Intermittent Control Strategy for Postural Balancing Using an EMG-Based Human-Computer InterfacePLOS ONE, 2013
- Accuracy of Specific BIVA for the Assessment of Body Composition in the United States PopulationPLOS ONE, 2013
- Biomedical Implementation of Liquid Metal Ink as Drawable ECG Electrode and Skin CircuitPLOS ONE, 2013
- Conductive Polymer Combined Silk Fiber Bundle for Bioelectrical Signal RecordingPLOS ONE, 2012
- Online estimation of internal resistance and open-circuit voltage of lithium-ion batteries in electric vehiclesJournal of Power Sources, 2011
- Linear parameter varying battery model identification using subspace methodsJournal of Power Sources, 2011
- A technique for dynamic battery model identification in automotive applications using linear parameter varying structuresControl Engineering Practice, 2009
- Analysis and Design of Wide-Band Digital Transmission in an Electrostatic-Coupling Intra-Body Communication SystemIEICE Transactions on Communications, 2009
- A model for human skin impedance during surface functional neuromuscular stimulationIEEE Transactions on Rehabilitation Engineering, 1999