Abstract
This paper proposes an imaging method for two-tap pulsed-based indirect time-of-flight (I-TOF) sensor, which aims to reduce distance error and motion artifact. Compared with the conventional imaging method, the proposed imaging method adopts emitted pulse light whose width is halved and height is doubled without changing the CMOS image sensor (CIS) system. Then, by using the distance-solving method that cooperates with this timing, it achieves depth imaging with the same range of distance measurement as the conventional method. The validity of the proposed method is demonstrated by the pixel-array behavior-level model based on the actual I-TOF imaging system. The experimental results show that compared with the conventional method, the distance error and motion artifact are reduced by 29.2% and 67.4%, respectively, under 350 mW/sr light source radiation intensity, 10 klux background illumination, and 500 us integration time. When the above parameters are changed, the proposed method still achieves about 29.3% reduction in distance error and 67.4% reduction in motion artifact. The proposed method is compatible with other methods to further reduce the distance error and motion artifact.
Funding Information
  • National Key Research and Development Program of China (2019YFB2204302)

This publication has 21 references indexed in Scilit: