Two main problems, including unbalanced grid input and circuit parameters uncertainty in the three-phase soft-switching converter control system, are considered in this paper. First, the constant-switching-frequency model-predictive control (CF-MPC) is improved for application in compound active-clamp zero-voltage-switching three-phase power factor correction converter. Second, a robust-constant-frequency model-predictive control (RCF-MPC) method is proposed for current loop; the novel contributions are: 1) the negative-sequence current component is introduced into the cost function of the model-predictive control to decrease the influence of unbalanced grid input; and 2) a robust item is added into the predictive model to reduce the influence of the circuit parameter uncertainty. Third, a robust variable structure controller is proposed for voltage loop considering the capacitor and load uncertainty. The simulation and experiment results show that, compared with the original CF-MPC method and the traditional proportional-integral control method, the proposed RCF-MPC method decreases the total harmonic distortion under the unbalanced grid condition. Meanwhile, the voltage loop robust variable structure controller has better transient and steady-state performance with respect to the load perturbation.
Funding Information
  • Innovative Research Team of Shaanxi Province (2013KCT-04)
  • Key Program of the Natural Science Foundation of Shaanxi Province (2016ZDJC-01)
  • National Science Foundation of China (61533014)
  • Research and Development Project of Beilin District of Xi’an City (GX1503, GX1713)
  • Xi’an University of Technology Scientific Research Projects (2015TS018, 2016CX042)

This publication has 22 references indexed in Scilit: