Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and ExacTrac stereoscopic imaging
Authors:
- 26 April 2021
- journal article
- research article
- Published by Springer Nature in La radiologia medica
- Vol. 126 (7) , 979-988
Abstract
Accurate calculation of set-up margin is a prerequisite to arrive at the most optimal clinical to planning target volume margin. The aim of this study was to evaluate the compatibility of different on-board and in-room stereoscopic imaging modalities by calculating the set-up margins (SM) in stereotactic body radiotherapy technique accounting and unaccounting for rotational positional errors (PE). Further, we calculated separate SMs one based on residual positional errors and another based on residual + intrafraction positional errors from the imaging data obtained in a dual imaging environment. A total of 22 lung cancer patients were included in this study. For primary image guidance, four-dimensional cone beam computed tomography (4-D CBCT) was used and stereoscopic ExacTrac was used as the auxiliary imaging. Following table position correction (TPC) based on the initial 4-D CBCT, another 4-D CBCT (post-TPC) and a pair of stereoscopic ExacTrac images were obtained. Further, during the treatment delivery, a series of ExacTrac images were acquired to identify the intrafraction PE. If a, b and c were the observed translational shifts in lateral (x-axis), longitudinal (y-axis) and vertical direction (z-axis) and α, β and γ were the rotational shifts in radians about the same axes, respectively, then the resultant translational vectors (A, B and C) were calculated on the basis of translational and rotational values. Set-up margins were calculated using residual errors post-TPC only and also using intrafraction positional errors in addition to the residual errors. Residual and residual + intrafraction SM were calculated from a dataset of 82 CBCTs and 189 ExacTrac imaging sessions. CBCT-based mean ± SD shifts in translational and rotational directions were 0.3 ± 1.8 mm, 0.1 ± 1.8 mm, − 0.4 ± 1.6 mm, 0.1 ± 0.4°, 0.0 ± 1.0° and 0.3 ± 0.7°, respectively, and for ExacTrac − 0.1 ± 1.8 mm, 0.2 ± 2.4 mm, − 0.6 ± 1.8 mm, 0.1 ± 1.2°, − 0.2 ± 1.3° and − 0.1 ± 0.6°, respectively. Residual SM without considering the rotational correction in x, y and z directions were 5.0 mm, 4.5 mm and 4.4 mm; rotation-corrected SM were 4.4 mm, 4.0 mm and 5.5 mm, respectively. Residual plus intrafraction SM were 5.5 mm, 6.6 mm and 6.2 mm without considering the rotational corrections, whereas they were 5.0 mm, 6.3 mm and 6.2 mm with rotational errors accounted for. Accurate calculation of set-up margin is required to find the clinical to planning target volume margin. Primary and auxiliary imaging margins fall in the range of 4.0 to 5.5 mm and 5.0 to 7.0 mm, respectively, indicating a higher SM for X-ray-based planar imaging techniques over three-dimensional cone beam images. This study established the degree of mutual compatibility between two different kinds of widely used set-up imaging modalities, on-board CBCT and in-room stereoscopic imaging ExacTrac. It also describes the technique to calculate the residual and residual plus intrafraction SM and its variation in a dual imaging environment accounting for rotational PE in stereotactic body radiotherapy of lung.Keywords
This publication has 31 references indexed in Scilit:
- EP-1641: PTV margin calculation and time dependency monitoring of intrafraction isocenter movement in lung SBRT by ExacTracRadiotherapy and Oncology, 2014
- Volumetric-Modulated Arc Therapy for Stereotactic Body Radiotherapy of Lung Tumors: A Comparison With Intensity-Modulated Radiotherapy TechniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Effect of Image-Guidance Frequency on Geometric Accuracy and Setup Margins in Radiotherapy for Locally Advanced Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung CancerJAMA, 2010
- Stereotactic Body Radiation Therapy for Early-Stage Non–Small-Cell Lung Carcinoma: Four-Year Results of a Prospective Phase II StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Outcome in a Prospective Phase II Trial of Medically Inoperable Stage I Non–Small-Cell Lung Cancer Patients Treated With Stereotactic Body RadiotherapyJournal of Clinical Oncology, 2009
- First clinical cone-beam CT imaging during volumetric modulated arc therapyRadiotherapy and Oncology, 2009
- Repositioning Accuracy of a Commercially Available Double-vacuum Whole Body Immobilization System for Stereotactic Body Radiation TherapyTechnology in Cancer Research & Treatment, 2004
- Errors and margins in radiotherapySeminars in Radiation Oncology, 2004
- Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995