Abstract
In order to study the effect of water adsorbed on the alumina coating of fluorescent lamps 35 W tubes were prepared by so setting the manufacturing process as not to fully remove contaminants. The light intensity has been measured along the tubes, showing a fast drop after the initial illumination at switching on. The minimum intensity was followed by a recovery of the light output, the brightening extending gradually from the liquid mercury reservoir of the tube. To explain the observations the reaction between mercury ions and water and its decomposition products (OH and H radicals) were considered, which decreases the free mercury concentration and thus the light output. Density functional calculations indeed indicate a strong binding between these species.