Optimized Identification of Triacylglycerols in Milk by HPLC-HRMS
Open Access
- 31 March 2022
- journal article
- research article
- Published by Springer Nature in Food Analytical Methods
- Vol. 15 (8) , 2084-2094
Abstract
This work has developed an optimized workflow for the targeted analysis of triacylglycerols (TAGs) in milk by liquid chromatography coupled with a Q-Exactive Orbitrap mass spectrometer. First, the effects of resolution (17,500; 35,000; 70,000; 140,000) and automatic gain control target (AGC, from 2×104, 2×105, 1×106, and 3×106) have been optimized with the goal to minimize the injection time, maximize the number of scans, and minimize the mass error. Then, the flow rate of the liquid chromatography system was also optimized by maximizing the number of theoretical plates. The resulting optimized parameters consisted of a flow rate of 200 μL/min, mass resolution of 35,000, and AGC target of 2×105. Such optimal conditions were applied for targeted TAG analysis of milk fat extracts. Up to 14 target triglycerides in milk fat were identified performing a data-dependent HPLC-HRMS-MS2 experiment (t-SIM-ddMS2). The findings reported here can be helpful for MS-based lipidomic workflows and targeted milk lipid analysis.Keywords
This publication has 46 references indexed in Scilit:
- Development of an Offline Bidimensional High-Performance Liquid Chromatography Method for Analysis of Stereospecific Triacylglycerols in Cocoa Butter EquivalentsJournal of Agricultural and Food Chemistry, 2013
- Orbitrap Mass SpectrometryAnalytical Chemistry, 2013
- Triacylglycerol and melting profiles of milk fat from several speciesInternational Dairy Journal, 2012
- Chromatographic analyses of fatty acid methyl esters by HPLC-UV and GC-FIDJournal of the Brazilian Chemical Society, 2012
- Effect of mass spectrometric parameters on peptide and protein identification rates for shotgun proteomic experiments on an LTQ‐orbitrap mass analyzerProteomics, 2011
- Characterization of fatty acid and triacylglycerol composition in animal fats using silver-ion and non-aqueous reversed-phase high-performance liquid chromatography/mass spectrometry and gas chromatography/flame ionization detectionJournal of Chromatography A, 2011
- Use of benchtop exactive high resolution and high mass accuracy orbitrap mass spectrometer for screening in horse doping controlAnalytica Chimica Acta, 2011
- More than 100,000 Detectable Peptide Species Elute in Single Shotgun Proteomics Runs but the Majority is Inaccessible to Data-Dependent LC−MS/MSJournal of Proteome Research, 2011
- Lipid extraction by methyl-tert-butyl ether for high-throughput lipidomicsJournal of Lipid Research, 2008
- Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass SpectrometerAnalytical Chemistry, 2006