How to Design the Optimal Stent Graft — What Have We Learnt?
Author:
- 1 June 2008
- journal article
- review article
- Published by SAGE Publications in Scandinavian Journal of Surgery
- Vol. 97 (2) , 191-194
Abstract
It is now more than 20 years since the first report of stent graft insertion in the human arterial system was published. The first “homemade” devices proved that the technique was possible but could not show any durability. Using these devices, it was possible to get a good seal but not a good anchorage. Not even the first generation of commercially available stent grafts proved to be durable. First after gaining knowledge about the forces acting on the stent graft, it was realized that attachment was important for the durability and the hooks and barbs or a longitudinal stability are needed to minimise the risk for distal migration. Not much of a difference in the overall performance is noticed between the ePTFE graft or the polyester graft or when comparing stainless steel stents with those made out of nitinol. The systems are made much more flexible and hydrophilic leading to a better performance and a greater chance of percutaneous approach. The optimal stent graft is not out on the market yet, but hopefully will come with further development.Keywords
This publication has 28 references indexed in Scilit:
- Sac behavior after aneurysm treatment with the Gore Excluder low-permeability aortic endoprosthesis: 12-month comparison to the original Excluder deviceJournal of Vascular Surgery, 2006
- Fascia Suturing of Large Access Sites After Endovascular Treatment of Aortic Aneurysms and DissectionsJournal of Endovascular Therapy, 2006
- Six-Year Experience With Talent Stent-Graft Repair of Abdominal Aortic AneurysmsJournal of Endovascular Therapy, 2005
- Effect of Suprarenal Stent Struts on the Renal Artery with Ostial Calcification Observed on CT Virtual Intravascular EndoscopyEuropean Journal of Vascular and Endovascular Surgery, 2004
- Late abdominal aortic aneurysm enlargement after endovascular repair with the excluder deviceJournal of Vascular Surgery, 2004
- Management of Aneurysm Sac HygromaJournal of Endovascular Therapy, 2004
- Endotension is Influenced by Wall Compliance in a Latex Aneurysm ModelEuropean Journal of Vascular and Endovascular Surgery, 2004
- Intra-aneurysm Sac Pressure – The Holy Grail of Endoluminal Grafting of AAAEuropean Journal of Vascular and Endovascular Surgery, 2002
- Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repairJournal of Vascular Surgery, 1996
- Endovascular exclusion of juxtarenal anastomotic pseudoaneurysmEuropean Journal of Vascular and Endovascular Surgery, 1996