Electrical tree growth and partial discharge in epoxy resin under combined AC and DC voltage waveforms
Authors:
- 5 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 25 (6) , 2183-2190
Abstract
The effect of DC bias on electrical tree growth and partial discharge (PD) characteristics in epoxy resin (Araldite LY® 5052/Aradur® HY 5052 supplied by Huntsman) is investigated using three waveforms: AC, AC with positive DC bias, and AC with negative DC bias. Needle-plane samples are used. Tree growth is shown to be accelerated by the combined effect of DC and 50 Hz AC, beyond the AC growth rate. Positive and negative DC biased tests result in 62% and 54% reductions in average time to breakdown, respectively. Different tree structures and stages of development are associated with different partial discharge characteristics, with thick dark tree branches associated with high PD magnitudes, whereas fine tree channel growth is linked with PD magnitudes below 1 pC. AC tests showed five distinct stages of tree growth compared to four stages seen in DC biased tests. In particular, trees growing in the `reverse direction' from the planar to the point electrode, which is observed in the latter stages of AC tests, is not seen in the DC biased tests. It is concluded that for composite voltages, the AC component is the essential driver of tree growth but the DC component can accelerate propagation. AC noise may therefore compromise the reliability of insulation in HVDC networks.Keywords
This publication has 18 references indexed in Scilit:
- DC electrical tree growth in epoxy resin and the influence of the size of inceptive AC treesIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- Electrical tree growth in epoxy resin under DC voltages2016
- The dynamic character of partial discharge in epoxy resin at different stages of treeing2016
- Partial discharge energy and electrical tree volume degraded in epoxy resin2015
- The impact of DC bias on electrical tree growth characteristics in epoxy resin samples2015
- Water tree growth of wet XLPE insulation stressed with DC and high frequency AC2012
- Model for partial discharges associated with treeing breakdown: III. PD extinction and re-growth of treeJournal of Physics D: Applied Physics, 2000
- A novel physical model for partial discharge in narrow channelsIEEE Transactions on Dielectrics and Electrical Insulation, 1999
- The correlation between the partial discharge behaviour and the spatial and temporal development of electrical trees grown in an epoxy resinJournal of Physics D: Applied Physics, 1996
- Analysis and modelling of electrical tree growth in synthetic resins over a wide range of stressing voltageJournal of Physics D: Applied Physics, 1994