Computer-aided auscultation of murmurs in children: evaluation of commercially available software
- 20 January 2016
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 26 (7) , 1359-1364
Abstract
Background: Heart murmurs are common in children and may represent congenital or acquired cardiac pathology. Auscultation is challenging and many primary-care physicians lack the skill to differentiate innocent from pathologic murmurs. We sought to determine whether computer-aided auscultation (CardioscanTM) identifies which children require referral to a cardiologist.Methods: We consecutively enrolled children aged between 0 and 17 years with a murmur, innocent or pathologic, being evaluated in a tertiary-care cardiology clinic. Children being evaluated for the first time and patients with known cardiac pathology were eligible. We excluded children who had undergone cardiac surgery previously or were unable to sit still for auscultation. CardioscanTMauscultation was performed in a quiet room with the subject in the supine position. The sensitivity and specificity of a potentially pathologic murmur designation by CardioscanTM– that is, requiring referral – was determined using echocardiography as the reference standard.Results: We enrolled 126 subjects (44% female) with a median age of 1.7 years, with 93 (74%) having cardiac pathology. The sensitivity and specificity of a potentially pathologic murmur determination by CardioscanTMfor identification of cardiac pathology were 83.9 and 30.3%, respectively, versus 75.0 and 71.4%, respectively, when limited to subjects with a heart rate of 50–120 beats per minute. The combination of a CardioscanTMpotentially pathologic murmur designation or an abnormal electrocardiogram improved sensitivity to 93.5%, with no haemodynamically significant lesions missed.Conclusions: Sensitivity of CardioscanTMwhen interpreted in conjunction with an abnormal electrocardiogram was high, although specificity was poor. Re-evaluation of computer-aided auscultation will remain necessary as advances in this technology become available.Keywords
This publication has 17 references indexed in Scilit:
- The Impact of Computer‐assisted Auscultation on Physician Referrals of Asymptomatic Patients with Heart MurmursClinical Cardiology, 2008
- Phono-spectrographic analysis of heart murmur in childrenBMC Pediatrics, 2007
- Guidelines and Standards for Performance of a Pediatric Echocardiogram: A Report from the Task Force of the Pediatric Council of the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2006
- Usefulness of a new sound spectral averaging technique to distinguish an innocent systolic murmur from that of aortic stenosisThe American Journal of Cardiology, 2005
- Helping family physicians improve their cardiac auscultation skills with an interactive CD-ROMJournal of Continuing Education in the Health Professions, 2002
- Artificial Neural Network–Based Method of Screening Heart Murmurs in ChildrenCirculation, 2001
- Cardinal Clinical Signs in the Differentiation of Heart Murmurs in ChildrenArchives of Pediatrics & Adolescent Medicine, 1996
- Reappraisal of the approach to the child with heart murmurs: is echocardiography mandatory?International Journal of Cardiology, 1988
- Noninvasive Tests in the Initial Evaluation of Heart Murmurs in ChildrenNew England Journal of Medicine, 1983
- Congenital Heart Disease in 56,109 Births Incidence and Natural HistoryCirculation, 1971