Biocompatibility and radiosensitivity of a fiber optical-based dosimeter: biological applications
- 30 April 2024
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (5) , 3492-3506
Abstract
This study introduces a cutting-edge fiber-optic dosimetry (FOD) sensor designed for measuring radiation in biological settings. The accuracy and precision of dosimeters for small animals, particularly prolonged exposure to nonuniform radiation fields, are always challenging. A state-of-the-art in-vivo dosimeter utilizing glass-encapsulated Thermoluminescence cylindrical detector (TLD) was introduced. The FODs are implanted into the rat during a prolonged irradiation scenario involving 137Cs where the rat has the freedom to move within a heterogeneous radiation domain. The implantation surgery was verified with X-ray computed tomography (CT) in addition to biochemical and pathological tests to assess the biocompatibility of FOD in vivo. A versatile FOD is designed for industrial and medical fields, which demand accurate and resilient radiation dosimeters. The dose measurements are associated with precise two-dimensional (2D) radiation distribution imaging. Three cylindrical FODs and three standards TLD_100 for each rat were tested. The measurements of peak irradiation before and after exposure reveal greater stability and superior sensitivity when compared to standard thermo-luminescence detectors in an in-vivo animal test. To the best of our knowledge, FOD testing on live animals is presented for the first time in this paper. Regarding the safety and biocompatibility of FOD, no morphological signs with any kind of inflammation or sensitivity toward the FOD material have been remarked. Moreover, with the current FOD, there is no oedema between the epidermal, dermal, and subdermal sections at the site of implantation. The results also show the stable levels of white blood cells (lymphocytes, granulocytes, MID) as blood inflammatory markers before surgery and at the time of extraction of the implanted dosimeters, thus confirming the biocompatibility for each optical fiber cylinder dosimeter. As a result, the new dosimeters have excellent biocompatibility in living tissues and have 100% accurate reusability intensity of the delivered radiation doses compared to TLD_100 which demonstrated a 45% reduction in its intensity accuracy.Keywords
Funding Information
- National Science and Technology Council (NSTC 112-2811-E-006-047)
This publication has 40 references indexed in Scilit:
- Advanced refractive index sensor based on photonic crystal fiber with elliptically split coresOptical and Quantum Electronics, 2023
- Biocompatible optical fiber for photomedical applicationGiant, 2023
- Collapsed photonic crystal fibre thermoluminescence dosimetry for external beam radiotherapyJournal of Radiation Research and Applied Sciences, 2023
- Investigation of thermoluminescence response and trapping parameters of natural barite samples from Dongargaon mine, IndiaLuminescence, 2020
- Thermoluminescence dosimetry properties and kinetic analysis of K3Ca2(SO4)3F:Dy3+ phosphorLuminescence, 2020
- Dosimetric features and kinetic parameters of a glass system dosimeterLuminescence, 2019
- Catalytically active cerium oxide nanoparticles protect mammalian cells from endogenous reactive oxygen speciesMaterials Today: Proceedings, 2019
- Biocompatibility of common implantable sensor materials in a tumor xenograft modelJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2018
- Investigation of the use of Ge-doped optical fibre for in vitro IMRT prostate dosimetryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Figure-of-merit (FOM), an improved criterion over the normalized chi-squared test for assessing goodness-of-fit of gamma-ray spectral peaksNuclear Instruments and Methods, 1977