Abstract
The purpose of this study was to identify optimal CT acquisition parameter settings for each make and model of scanners used in a large Radiation Oncology (RO) Department, considering the special requirements of CT simulation. 2 CT phantoms were used to evaluate the image quality of the five different multi-channel CT scanners using helical scan mode. We compared the effects of various pitch, detector configurations, and rotation time parameters on image artifacts and on spatial and contrast resolution. We found that helical artifact was closely related to pitch and detector configuration settings. This artifact was scanner specific and generally more obvious when the channel width, or detector collimation, was equal to the image thickness. Different acquisition parameter settings produced slight differences in observed high- and low-contrast resolution. Short rotation time degraded image quality for certain scanners, but only slightly, while other rotation times, such as 0.75s/rotation and above, had no obvious effect on resolution. An optimized combination of acquisition parameters was determined for each scanner make and model, based on phantom image quality and other considerations for clinical applications. This information may be directly useful for physicists whose CT simulation scanners match one examined in this study. If not, the strategy reported here may be used as a guide to perform a similar evaluation of the scanner.Keywords
This publication has 10 references indexed in Scilit:
- The Measurement, Reporting, and Management of Radiation Dose in CT2008
- Abdominal Multislice CT for Obese Patients: Effect on Image Quality and Radiation Dose in a Phantom StudyAcademic Radiology, 2007
- Technical optimization of four-channel multidetector-row helical computed tomography for depicting arterial stenosis: a phantom studyActa Radiologica, 2007
- Multi-Detector row CT urography on a 16-row CT scanner in the evaluation of urothelial tumorsEuropean Radiology, 2006
- Scanning protocols for multislice CT scannersBritish Journal of Radiology, 2004
- The impact of tumor motion upon CT image integrity and target delineationMedical Physics, 2004
- Optimization of Eight-Element Multi–Detector Row Helical CT Technology for Evaluation of the AbdomenRadiology, 2003
- CT simulation for radiotherapy treatment planningBritish Journal of Radiology, 2002
- AAPM/RSNA Physics Tutorial for Residents: Topics in CTRadioGraphics, 2002
- Optimization of scanning parameters for CT colonographyBritish Journal of Radiology, 2002