Extra-Cavity Image Registration via the Aortic Root During Left Ventricular Mapping and Ablation
Author:
Open Access
- 1 January 2024
- journal article
- research article
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 28 (4) , 201-207
Abstract
Background: Computed tomography (CT) image integration is of limited use in left ventricular (LV) ablation due to inadequate accuracy of registration. The current study aimed to investigate the accuracy and feasibility of extra-cavity LV image registration via the coronary cusp. Methods: Consecutive patients were enrolled as the validation group (n = 41) and feasibility group (n = 48). After extra-cavity registration via the aortic root, the LV anatomy derived from CT image was activated and moved into real space. Accuracy of LV anatomy via this registration method was verified by intracardiac echocardiography reconstruction in the validation group and tested further in the feasibility group via measuring the location differences (<3 mm) and volume difference (<8 mL). Results: In validation group, the LV volume of CT image and ICE map were comparable (113.6 +/- 15.5 mL vs. 109.0 +/- 15.3 mL, P = .27), and the location difference was 3.1 +/- 1.1 mm at LV summit, 1.8 +/- 0.9 mm at the free wall, and 1.8 +/- 0.7 mm at the LV apex. There was a mean of 2.9 +/- 1.2 mm and 3.0 +/- 1.0 mm length difference in anterior PM and posterior PM, the position difference of the PM's base was 2.8 +/- 0.9 mm for anterior PM and 2.2 +/- 0.9 mm for posterior PM. In feasibility group, the distance differences of LV summit, LV septum, LV apex, and LV free averaged 1.8 +/- 0.8 mm, 1.5 +/- 0.7 mm, 1.4 +/- 0.6 mm, 1.3 +/- 0.7 mm, respectively. Compared with validation group, acute success (100% vs. 96.5%, P = .51), complications rate (4.9% vs. 2.0%, P = 0.59) and fluoroscopic time (1.6 +/- 1.1 vs. 1.9 +/- 1.6 minutes, P = .30) exhibited no significant difference, but was significantly reduced with procedure time (74.5 +/- 8.1 vs. 61.2 +/- 9.5 minutes, P < .001) with CT image registration only. Conclusion: LV mapping and ablation could be successfully achieved by extra -cavity registration via coronary cusp without needing positions within LV beforehand.Keywords
This publication has 15 references indexed in Scilit:
- Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experienceEP Europace, 2011
- Visualization of multiple catheters with electroanatomical mapping reduces X-ray exposure during atrial fibrillation ablationEP Europace, 2011
- Ablation of atrial fibrillation: does the addition of three-dimensional magnetic resonance imaging of the left atrium to electroanatomic mapping improve the clinical outcome?: A randomized comparison of Carto-Merge vs. Carto-XP three-dimensional mapping ablation in patients with paroxysmal and persistent atrial fibrillationEP Europace, 2010
- Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMergeTM Italian RegistryEP Europace, 2009
- Image integration in electroanatomic mappingHerzschrittmachertherapie + Elektrophysiologie, 2007
- Registration of 3D computed tomographic images with interventional systems: Implications for catheter ablation of atrial fibrillationJournal of Interventional Cardiac Electrophysiology, 2006
- Integration of Cardiac CT/MR Imaging with Three‐Dimensional Electroanatomical Mapping to Guide Catheter Manipulation in the Left Atrium: Implications for Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided AblationsCirculation, 2006
- Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system†European Heart Journal, 2005
- Voltage and Activation MappingCirculation, 2003