Vital capacity breath technique for rapid anaesthetic induction: comparison of sevoflurane and isoflurane
Authors:
- 1 November 1992
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 47 (11) , 946-949
Abstract
Summary: This study compares vital capacity rapid inhalational induction of anaesthesia with sevoflurane and isoflurane. Forty‐six volunteers undergoing the procedure had one of the two agents: 25 had sevoflurane and 21 isoflurane. Subjects were unpremedicated and breathed approximately 1.7 MAC equivalents of either vapour. There were no significant differences in the patients' monitored cardiovascular, respiratory, and electrocardiographs variables. The mean time for induction of anaesthesia with sevoflurane (120 s) was significantly shorter than with isoflurane (145 s), reflecting its higher blood‐gas solubility. There were fewer induction complications in the sevoflurane group. Subjects in the sevoflurane group found the induction of anaesthesia more pleasant and were more willing to undergo it again compared to subjects in the isoflurane group. We conclude that sevoflurane is superior to isoflurane in vital capacity rapid inhalational induction of anaesthesia, particularly in instances where premedication should be avoided.Keywords
This publication has 9 references indexed in Scilit:
- Rapid Induction of Anesthesia with IsolfluraneAnesthesia & Analgesia, 1988
- SINGLE BREATH INDUCTION OF ANAESTHESIA WITH ISOFLURANEBritish Journal of Anaesthesia, 1987
- Toxicity of Sevoflurane in RatsAnesthesia & Analgesia, 1987
- Comparison of Halothane and Isoflurane for Rapid Anesthetic InductionAnesthesia & Analgesia, 1987
- Partition Coefficients for Sevoflurane in Human Blood, Saline, and Olive OilAnesthesia & Analgesia, 1987
- The Minimum Alveolar Concentration (MAC) of Sevoflurane in HumansAnesthesiology, 1987
- Induction and recovery characteristics of isoflurane and halothane anaesthesia for short outpatient operations in childrenAnaesthesia, 1985
- RAPID INDUCTION OF HALOTHANE ANAESTHESIA IN MANBritish Journal of Anaesthesia, 1985
- Minimum Alveolar Concentrations (MAC) of Isoflurane with and without Nitrous Oxide in Patients of Various AgesAnesthesiology, 1975