Development of a High-Precision Calorimeter for Measuring Power Loss in Electrical Machines
Authors:
- 26 September 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 58 (3) , 570-577
Abstract
This paper is concerned with the development of a high-precision 30-kW (40-hp) calorimeter and is specifically focused on how experimental errors resulting from calorimeter design and operating procedures are eliminated or mitigated. A complete calibration for the calorimetric system using a DC heater is conducted, and two induction motors rated at 5.5 and 30 kW (7 and 40 hp, respectively) are carefully tested both within and outside of the calorimeter. Loss segregation is in accordance with the IEEE 112 method B. Experimental results for the comparison of calorimetric and input-output methods clearly confirm the effectiveness of the calorimeter in terms of accurate power loss measurement. The accuracy of the calorimeter is approximately 5.6 W in the measurement of power loss of up to 4.5 kW with a resolution of 0.1 W.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of Stray Load Loss in Induction Motors With a Comparison of Input–Output and Calorimetric MethodsIEEE Transactions on Energy Conversion, 2006
- Calorimetric Measuring Systems: Characterizing High-Frequency Power Losses in Power Electronic Components and SystemsIEEE Industry Applications Magazine, 2004
- Precision calorimetry for the accurate measurement of inverter losses2004
- Stray Load Loss Analysis of Induction Motor—Comparison of Measurement Due to IEEE Standard 112 and Direct Calculation by Finite-Element MethodIEEE Transactions on Industry Applications, 2004
- High precision calorimetry for the measurement of the efficiency of induction motors2002
- Design and implementation of a calorimetric measurement facility for determining losses in electrical machinesIEEE Transactions on Instrumentation and Measurement, 2002
- Double chamber calorimeter (DCC): a new approach to measure induction motor harmonic lossesIEEE Transactions on Energy Conversion, 1999
- Design of a double-jacketed, closed type calorimeter for direct measurement of motor losses1998
- An automated calorimetric method of loss measurement in electrical machinesJournal of Magnetism and Magnetic Materials, 1994
- A calorimeter for optical fiber power standard and advantages in calibration of optical fiber power metersIEEE Transactions on Instrumentation and Measurement, 1993