Care Study: A critical event in tracheostomy care
Author:
- 22 June 1995
- journal article
- case report
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 4 (12) , 676-681
Abstract
Albert Collis is an 80-year-old man who was admitted to the intensive care unit with an episode of acute pancreatitis, 6 weeks before a critical incident in his tracheostomy care. His pancreatitis was managed medically, with part of this treatment involving mechanical ventilation. Although the pancreatitis responded well to treatment, Albert developed a chest infection and proved difficult to wean from the ventilator. A tracheostomy was therefore performed 2 weeks after admission, both for Albert's comfort and to facilitate the weaning process. Albert's muscles had wasted considerably during his admission and his respiratory muscles were very weak. In the 4 weeks following his tracheostomy he had progressed slowly from pressure control mode to synchronised intermittent mandatory ventilation and pressure support, to pressure support only. He then went on to a continuous positive airway pressure circuit, and for the 2 days before the incident had been on a T-piece with a thermovent humidifier with 28% oxygen. Despite copious loose yellow secretions, which Albert was now managing to cough clear of the tube himself, his oxygen saturations ranged constantly between 96% and 98%. As a result of his strong cough, Albert was only occasionally suctioned and was encouraged to clear his own secretions with the aid of nurses, physiotherapists and tissues! Albert's main problem at this time was boredom and irritability, which caused him to remove the T-piece from his tracheostomy tube frequently; when he was breathing on air alone his oxygen saturation was only 89-90%. The importance of both the oxygen and humidification was explained to Albert and the T-piece was replaced as often as he allowed. At approximately 8.30 am on the third morning of being on the T-piece, Albert's oxygen saturation level dropped to 85% from 96%. His T-piece was still in position and the supply was connected. The oxygen saturation probe site was checked and was shown to be reading correctly. Air entry on auscultation was quiet in all areas, but was present. As a temporary measure, the inspired level of oxygen was increased to 40%, but had no effect. A decision was therefore made to hand-ventilate Albert with the aid of a re-breathing bag and 100% oxygen. Sterile saline 3 ml was instilled into his tracheostomy tube and suctioned. On suctioning, the lumen of the tube was found to be very narrow, and difficulty was experienced in passing the suction catheter. Further hand-ventilation, saline and suctioning produced thick yellow secretions and the lumen of the tube cleared sufficiently to enable the suction catheter to be passed easily. Albert's oxygen saturations were now 99% on 100% oxygen and he was placed back on the thermovent and T-piece with 28% oxygen. His saturations returned to their baseline level of 96% and remained at this level. Auscultation revealed good air entry to all areas of the lungs.Keywords
This publication has 10 references indexed in Scilit:
- Potential hazards of tracheobronchial suctioningIntensive and Critical Care Nursing, 1992
- SAFE SUCTIONINGNursing, 1989
- Endotracheal SuctioningAnnual Review of Nursing Research, 1989
- Laboratory evaluation of heat-and-moisture exchangersJournal of Anesthesia, 1989
- TRACH CARENursing, 1988
- LOWERING THE RISKS OF Endotracheal SuctioningNursing, 1988
- A review of the mechanisms and methods of humidification of inspired gasesIntensive Care Medicine, 1988
- A comparison of five heat and moisture exchangersAnaesthesia, 1986
- Comparison of Tracheobronchial Suction Catheters in HumansChest, 1976
- Cardiac Arrhythmias Resulting from Tracheal SuctioningAnnals of Internal Medicine, 1969