Validity and reliability of velocity and power measures provided by the Vitruve linear position transducer
Open Access
- 24 October 2024
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (10) , e0312348
Abstract
This study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables—regardless of relative loads and exercise modes—were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.Keywords
This publication has 28 references indexed in Scilit:
- Concurrent Validity of Field-Based Diagnostic Technology Monitoring Movement Velocity in Powerlifting ExercisesJournal of Strength & Conditioning Research, 2021
- Magnitude and Reliability of Velocity and Power Variables During Deadlifts Performed With and Without Lifting StrapsJournal of Strength & Conditioning Research, 2020
- Reliability and Concurrent Validity of Seven Commercially Available Devices for the Assessment of Movement Velocity at Different Intensities During the Bench PressJournal of Strength & Conditioning Research, 2019
- The Reliability of Individualized Load–Velocity ProfilesInternational Journal of Sports Physiology and Performance, 2018
- Reliability of power and velocity variables collected during the traditional and ballistic bench press exerciseSports Biomechanics, 2017
- Differential expression of genes related to gain and intake in the liver of beef cattleBMC Research Notes, 2017
- Comparison of the force-, velocity-, and power-time curves recorded with a force plate and a linear velocity transducerSports Biomechanics, 2016
- A Brief Review of Strength and Ballistic Assessment Methodologies in SportSports Medicine, 2014
- Comparison of Four Different Methods to Measure Power Output During the Hang Power Clean and the Weighted Jump SquatJournal of Strength & Conditioning Research, 2007
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998