Interaction between flicker-induced vasodilatation and pressure autoregulation in early retinopathy of Type 2 diabetes
- 12 February 2008
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 246 (5) , 763-769
Abstract
Background Diabetic retinopathy is accompanied with changes in the autoregulation of retinal blood flow secondary to changes in the systemic blood pressure and the retinal metabolism. In the present study we tested the working hypothesis that there is an interaction between these mechanisms that might be relevant for understanding and treating flow disturbances in diabetic retinopathy. Methods Fifty-four persons divided into three age and sex matched groups were studied: Group 1: twenty normal persons. Group 2: fourteen patients with type 2 diabetes mellitus and no diabetic retinopathy. Group 3: twenty type 2 diabetic patients with minimal diabetic retinopathy and a diabetes duration similar to that of the patients in group 2. Using the Retinal Vessel Analyzer (RVA) the diameter response of retinal arterioles was studied in all groups after an increase in the blood pressure by isometric exercise, during exposition to 8 Hz flickering light, and during simultaneous exposition to both stimulus conditions. Results The increased blood pressure induced by isometric exercise induced a non-significant vasoconstriction in the normal persons and in the diabetic patients without retinopathy (p = 0.10 and p = 0.84 respectively), and a non-significant vasodilatation in the diabetic patients with mild retinopathy (p = 0.10). The flicker stimulus elicited a significant vasodilatation of retinal arterioles that decreased significantly from the normal persons to the diabetic patients without and with retinopathy (linear regression, p < 0.01). The flicker-induced vasodilatation was not significantly affected by a simultaneous increase in the arterial blood pressure in normal persons (p = 0.85). Conversely, in the diabetic patients the reduced diameter response during flicker was counteracted by a simultaneous increase in the blood pressure, to a level not differing significantly from the response of normal persons (p = 0.75). Conclusions Intervention studies aimed at modifying perfusion in retinal disease should consider the interaction between different mechanisms for autoregulating retinal blood flow. New treatment modalities for retinal vascular disease might need to target several mechanisms of tone control in retinal arterioles simultaneously.Keywords
This publication has 23 references indexed in Scilit:
- Control of Retinal Arterial Tone by a Paracrine Retinal Relaxing FactorMicrocirculation, 2007
- ATP-Induced Relaxation of Porcine Retinal Arterioles Depends on the Perivascular Retinal Tissue and Acts Via an Adenosine ReceptorCurrent Eye Research, 2007
- Response of retinal arteriole diameter to increased blood pressure during acute hyperglycaemiaActa Ophthalmologica Scandinavica, 2006
- Chorioretinal Vascular Oxygen Tension Changes in Response to Light FlickerInvestigative Ophthalmology & Visual Science, 2006
- Effect of cyclic guanosine-monophosphate on porcine retinal vasomotionActa Ophthalmologica Scandinavica, 2006
- Myogenic response in isolated porcine retinal arteriolesCurrent Eye Research, 2003
- Reproduzierbarkeit der Messungen mit dem Retinal Vessel Analyzer unter OptimalbedingungenKlinische Monatsblätter für Augenheilkunde, 2002
- Retinal Blood Flow Regulation in Diabetes Mellitus: Impaired Autoregulation and No Detectable Effect of Autonomic Neuropathy Using Laser Doppler Velocimetry, Computer Assisted Image Analysis, and Isometric ExerciseMicrovascular Research, 1999
- Effect of Decreased Ocular Perfusion Pressure on Blood Flow and the Flicker-Induced Flow Response in the Cat Optic Nerve HeadMicrovascular Research, 1996
- Regional retinal blood flow and vascular autoregulationEye, 1996