Abstract
This article presents the effects of air exchange rate (ACH) and air exchange effectiveness (AEE) on thermal comfort level of a naturally ventilated office room. The study was conducted in an office at UPM, Malaysia. Influence of ACH and AEE on thermal comfort has not been investigated and is, therefore, not well understood. The main objective of this research is to investigate and assess these influences through the variable windows-door opening arrangements. To determine the windows-door opening performance in terms of ventilation air flow rate, 14 opening configurations have been considered. Thermal comfort variables were measured at the same time when ACH and AEE were evaluated. Through these data, the thermal comfort Fanger's indices (Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD)), ACH and AEE were calculated. These results showed that for a naturally ventilated office room three linear regression equations of PMV versus ACH and three linear regression equations of PMV versus AEE can be derived.Keywords
This publication has 11 references indexed in Scilit:
- The impacts of ventilation strategies and facade on indoor thermal environment for naturally ventilated residential buildings in SingaporeBuilding and Environment, 2007
- Using results from field surveys to predict the effect of open windows on thermal comfort and energy use in buildingsEnergy and Buildings, 2007
- Investigation of effects of window combinations on ventilation characteristics for thermal comfort in buildingsDesalination, 2007
- Effect of door opening on the performance of displacement ventilation in a typical office buildingBuilding and Environment, 2007
- Data-based mechanistic modelling approach to determine the age of air in a ventilated spaceBuilding and Environment, 2006
- Ventilation performance measurement using constant concentration dosing strategyBuilding and Environment, 2004
- Total air age: an extension of the air age conceptBuilding and Environment, 2003
- Experimental and theoretical analysis of natural ventilation by windows openingEnergy and Buildings, 2002
- Thermal comfort: use of controls in naturally ventilated buildingsEnergy and Buildings, 2001
- Development and application of an indoor air quality audit to an air-conditioned building in SingaporeBuilding and Environment, 2001