Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols
Authors:
- Alexia RossiARAlexia Rossi
- Tessa S. S. GendersTGTessa S. S. Genders
- Koen NiemanKNKoen Nieman
- Stella L. PapadopoulouSPStella L. Papadopoulou
- Anoeshka S. DharampalADAnoeshka S. Dharampal
- Carl J. SchultzCSCarl J. Schultz
- Annick C. WeustinkAWAnnick C. Weustink
- Marcel L. DijkshoornMDMarcel L. Dijkshoorn
- Gert-Jan R. Ten KateGKGert-Jan R. Ten Kate
- Admir DedicADAdmir Dedic
- Marcel van StratenMSMarcel van Straten
- 7 October 2012
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 23 (3) , 614-622
Abstract
To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction.We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients.In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P < 0.001). In group B (228 patients, 132 men, mean heart rate 75 ± 11 bpm), per-segment sensitivity, specificity, PPV and NPV were comparable (94 %, 95 %, 67 %, 99 % vs. 92 %, 95 %, 66 %, 99 %, P > 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups.Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose.Keywords
This publication has 27 references indexed in Scilit:
- SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CTJournal of Cardiovascular Computed Tomography, 2011
- Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT AngiographyJACC: Cardiovascular Imaging, 2011
- Feasibility and Radiation Dose of High-Pitch Acquisition Protocols in Patients Undergoing Dual-Source Cardiac CTAmerican Journal of Roentgenology, 2010
- Image Quality and Radiation Exposure With a Low Tube Voltage Protocol for Coronary CT AngiographyJACC: Cardiovascular Imaging, 2010
- ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 Appropriate Use Criteria for Cardiac Computed TomographyJACC, 2010
- Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot modeHeart, 2010
- Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisitionEuropean Heart Journal, 2009
- Ionizing Radiation in Cardiac ImagingCirculation, 2009
- Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters.American Journal of Roentgenology, 1993
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975