Automated Biomedical Signal Quality Assessment of Electromyograms: Current Challenges and Future Prospects
Authors:
- 25 January 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 25 (1) , 12-19
Abstract
This work is an exposition of research supporting efforts to automate quality assessment in surface electromyography (sEMG). Electromyography measures electrical activity from skeletal muscles, which are the muscles associated with voluntary movements. Skeletal muscles can consist of tens to hundreds of thousands of contractile fibers which are grouped into functional units called Motor Units (MUs). Each MU is driven to contract its fibers by electrochemical impulses sent from a motor neuron, and a muscle may contain anywhere from tens to hundreds of MUs. When an MU is activated, all fibers associated with it are simultaneously activated. When fibers are activated, an electrochemical impulse propagates along each of them to cause contraction. This impulse is known as a Single Fiber Action Potential (SFAP). A Motor Unit Action Potential (MUAP) is the summation of all SFAPs corresponding to an activated MU. To generate a continuous contraction, MUs are repeatedly activated, producing a train of MUAPs, and this pulse train is called the Motor Unit Action Potential Train (MUAPT). The combined electrical activity of all of the MUAPTs associated with a contraction, as recorded on the surface of the skin using non-invasive electrodes, is a surface electromyography (sEMG) signal. In general, it is not possible to directly observe the SFAPs, MUAPs, and MUAPTs non-invasively (though there have been algorithmic efforts to decompose sEMG signals into its constituent MUAPTs). SFAPs and MUAPTs can be observed by inserting needle electrodes into specific muscle regions for high spatial selectivity; however, such techniques are invasive, making surface measurements a desirable alternative. sEMG signals have been used in a wide variety of applications, including fatigue assessment, myoelectric control, diagnosis of neuromuscular disorders, and tracking performance in sports.Keywords
This publication has 22 references indexed in Scilit:
- Electromyography data for non-invasive naturally-controlled robotic hand prosthesesScientific Data, 2014
- Automated Biosignal Quality Analysis for Electromyography Using a One-Class Support Vector MachineIEEE Transactions on Instrumentation and Measurement, 2014
- Identification of Contaminant Type in Surface Electromyography (EMG) SignalsIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- Biosignal quality analysis of surface EMG using a correlation coefficient test for normality2013
- A note on the probability distribution function of the surface electromyogram signalBrain Research Bulletin, 2013
- Modeling nonlinear errors in surface electromyography due to baseline noise: A new methodologyJournal of Biomechanics, 2011
- Beyond Accuracy, F-Score and ROC: A Family of Discriminant Measures for Performance Evaluation2006
- Volume Conduction in an Anatomically Based Surface EMG ModelIEEE Transactions on Biomedical Engineering, 2004
- Deconvolution estimation of motor unit conduction velocity distributionIEEE Transactions on Biomedical Engineering, 2002
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000