Color Doppler flow mapping of the patent ductus arteriosus in very low birthweight neonates: Echocardiographic and clinical findings
Authors:
- 1 September 1994
- journal article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 15 (5) , 219-224
Abstract
Forty-eight preterm infants (mean birthweight 1.0±0.3 kg; mean gestational age 28±3 weeks) underwent serial echocardiograms and physical examinations in order to determine the correlation between color Doppler flow mapping (CDFM) results and physical findings of a patent ductus arteriosus (PDA), the predictive value of early CDFM as an indicator of subsequent requirement for treatment of a PDA, and to determine the direction and duration of ductal shunting and the rate of ductal closure and opening. CDFM analysis and cardiac physical examination of left-to-right ductal shunting were usually concordant in infants with a large PDA shunt, the most reliable physical finding being increased precordial activity. CDFM studies on day 2 or 3 of postnatal life had prognostic value with regard to subsequent need for closing the PDA. Additional findings included the absence of right-to-left PDA shunting in infants <1 kg and <28 weeks gestation and the absence of ductal reopening in infants in whom it had closed spontaneously. After complete PDA closure using indomethacin, subsequent ductal reopening is uncommon, except in infants <25 weeks gestation and <700 g bodyweight.Keywords
This publication has 19 references indexed in Scilit:
- Duration of ductal shunting in healthy preterm infants: An echocardiographic color flow doppler studyThe Journal of Pediatrics, 1988
- Persistent responsiveness of the neonatal ductus arteriosus in immature lambs: a possible cause for reopening of patent ductus arteriosus after indomethacin-induced closure.Circulation, 1985
- Patent ductus arteriosus in neonates with severe respiratory diseaseThe Journal of Pediatrics, 1984
- Continuous wave Doppler ultrasonographic quantitation of patent ductus arteriosus flowThe Journal of Pediatrics, 1982
- Specificity and accuracy of echocardiographic and clinical criteria for diagnosis of patent ductus arteriosus in fluid-restricted infantsThe Journal of Pediatrics, 1981
- Noninvasive detection of retrograde descending aortic flow in infants using continuous wave Doppler ultrasonographyThe Journal of Pediatrics, 1980
- Pulsatile aortopulmonary pressure-flow dynamics of patent ductus arteriosus in patients with various hemodynamic states.Circulation, 1980
- The silent ductus arteriosusThe Journal of Pediatrics, 1978
- Patent ductus arteriosus complicating the respiratory distress syndrome in preterm infantsThe Journal of Pediatrics, 1975
- Echocardiographic Assessment of Ductus Arteriosus Shunt in Premature InfantsCirculation, 1974