Combined numerical and experimental approach to determine numerical model of abdominal scaffold
Open Access
- 28 November 2021
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 25 (11) , 1235-1248
Abstract
A proper junction of the prosthesis and the abdominal wall is important in successful hernia repair. The number of tacks should be balanced to assure appropriate mesh fixation and not to induce post-operative pain. Numerical simulations help to find this balance. The study is aimed at creating a proper numerical model of a knitted surgical mesh subjected to boundary conditions and load occurring in the abdominal cavity. Continuous, anisotropic constitutive relation is considered to reflect the mesh behaviour. Different sets of material law parameters are determined on the basis of different bi-axial tests setups. Force- and displacement-controlled tests with different ratios are considered. Consequently, some numerical model variants are obtained featuring various reaction distributions in the scaffold fixation points. The proper variant is selected based on comparison of the position of maximal reaction force in the numerical model and in the reference physical model of operated hernia. Force-driven tests have shown anisotropic mesh behaviour, while equibiaxial displacement-driven test has demonstrated reduced anisotropic response. Within seven scenarios of constitutive parameters identification (based on single or combined experimental data), the equibiaxial force-controlled test appeared to produce the most relevant model to follow the prosthesis behaviour under pressure. The position of maximal reaction force in such model is similar to obtained in the physical hernia model. The equibiaxial force-driven test provides most suitable data for Gasser-Ogden-Holzapfel constitutive model identification of a considered surgical mesh to be used to model the mesh under pressure.Keywords
Funding Information
- the National Science Centre (UMO-2017/27/B/ST8/02518)
This publication has 34 references indexed in Scilit:
- Magnetic Resonance–Visible Meshes for Laparoscopic Ventral Hernia RepairJSLS : Journal of the Society of Laparoscopic & Robotic Surgeons, 2015
- Characterizing the ex vivo mechanical properties of synthetic polypropylene surgical meshJournal of the Mechanical Behavior of Biomedical Materials, 2014
- A physically based structural model for a textile prosthetic meshInternational Journal of Solids and Structures, 2014
- Behaviour of orthotropic surgical implant in hernia repair due to the material orientation and abdomen surface deformationComputer Methods in Biomechanics and Biomedical Engineering, 2013
- Mechanical Response of the Herniated Human Abdomen to the Placement of Different ProsthesesJournal of Biomechanical Engineering, 2013
- Computational framework to model and design surgical meshes for hernia repairComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Mechanical behaviour of synthetic surgical meshes: Finite element simulation of the herniated abdominal wallActa Biomaterialia, 2011
- Anisotropic evaluation of synthetic surgical meshesHernia, 2010
- Evaluation of dynamic creep properties of surgical mesh prostheses—Uniaxial fatigueJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2009
- Hyperelastic modelling of arterial layers with distributed collagen fibre orientationsJournal of The Royal Society Interface, 2005