EPR dosimetry in glass: a review
- 20 March 2022
- journal article
- review article
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (2) , 179-203
Abstract
Electron Paramagnetic Resonance (EPR) spectroscopy enables detection of paramagnetic centers generated in solids by ionising radiation. In the last years, the ubiquity of glass in personal utility items increased significance of fortuities retrospective dosimetry based on EPR in glass parts of mobile phones and watches. Despite of fading of the signals and their susceptibility to light, it enables dosimetry at medical triage level of 1–2 Gy. In this article information relevant for assessment of applicability and planning of the EPR dosimetry is presented—particularly at dose levels typical for radiation accidents. Reported data on fading of the radiation-induced spectral components are presented and compared. Effects of light on background spectra and on the dosimetric signals are also presented. It is concluded that when properly accounting for the fading and for the obscuring effects of light, the EPR dosimetry in glasses from mobile phones and watches can be used in dose assessment after radiation accidents.Keywords
Funding Information
- Medical University of Gdańsk (Internal Grant ST-70)
This publication has 58 references indexed in Scilit:
- Review of retrospective dosimetry techniques for external ionising radiation exposuresRadiation Protection Dosimetry, 2010
- Overview of physical and biophysical techniques for accident dosimetryRadiation Protection Dosimetry, 2010
- DENTAL ENAMEL EPR DOSIMETRY: COMPARATIVE TESTING OF THE SPECTRA PROCESSING METHODS FOR DETERMINATION OF RADIATION-INDUCED SIGNAL AMPLITUDEHealth Physics, 2010
- RADIATION ACCIDENT DOSIMETRY ON GLASS BY TL AND EPR SPECTROMETRYHealth Physics, 2010
- Q-BAND EPR BIODOSIMETRY IN TOOTH ENAMEL MICROSAMPLES: FEASIBILITY TEST AND COMPARISON WITH X-BANDHealth Physics, 2007
- Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performanceRadiation Measurements, 2007
- EPR dosimetry for actual and suspected overexposures during radiotherapy treatments in PolandRadiation Measurements, 2007
- Combined effects of high doses and temperature on radiation-induced radicals and their relative contributions to EPR signal in gamma-irradiated alanineRadiation Protection Dosimetry, 2006
- In Vivo Assessment of Radiation ExposureHealth Physics, 1991
- Defect centers in a pure-silica-core borosilicate-clad optical fiber: ESR studiesJournal of Applied Physics, 1976