The measurement of polarization and depolarization currents (PDC) based on time–domain response is an effective method for state assessment of cellulose insulation material in oil-immersed electrical equipment. However, the versatility of the data obtained at different temperatures is limited because of the temperature dependence of the PDC. In this respect, the universal conversion of PDC data at different temperatures is an essential aspect to improve the accuracy of the determination of insulating properties of cellulose materials immersed in the oil. Thus, an innovative temperature conversion method based on polarization time-varying current (PTC, obtained by multiplying the polarization current and time) is proposed in this article. In the current work, the PTC data at different temperatures are obtained from the oil-immersed cellulose pressboards with different moisture. Afterwards, the functional model based on the power series theory is used to simulate the PTC data, through which the coefficients of the power series are found related to the test temperature of the PTC and the moisture content (mc%) of the oil-immersed cellulose pressboards. Furthermore, the functional relationship among moisture, test temperatures, and the feature parameter calculated by these coefficients is established. Thus, the PTC data at various temperatures can be calculated by the established function. The potential application ability of the proposed method is verified by comparing the calculated results with the measured results obtained from the various samples.Keywords
Funding Information
- National Natural Science Foundation of China (61473272)
This publication has 33 references indexed in Scilit:
- Moisture Diagnosis of Transformer Oil-Immersed Insulation With Intelligent Technique and Frequency-Domain SpectroscopyIEEE Transactions on Industrial Informatics, 2020
- Aging evaluation and moisture prediction of oil-immersed cellulose insulation in field transformer using frequency domain spectroscopy and aging kinetics modelCellulose, 2020
- Improved method for aging assessment of winding hot-spot insulation of transformer based on the 2-FAL concentration in oilInternational Journal of Electrical Power & Energy Systems, 2019
- Calibration Proposal for UHF Partial Discharge Measurements at Power TransformersEnergies, 2019
- Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current TransducerEnergies, 2018
- A Review of Frequency Response Analysis Methods for Power Transformer DiagnosticsEnergies, 2016
- Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged TransformersEnergies, 2016
- Ageing of Mineral Oil Impregnated Cellulose by Acid CatalysisIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Dielectric response of mineral oil impregnated cellulose and the impact of agingIEEE Transactions on Dielectrics and Electrical Insulation, 2007
- Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformersIEE Proceedings - Science, Measurement and Technology, 1994