Interdigitated aluminium and titanium sensors for assessing epithelial barrier functionality by electric cell-substrate impedance spectroscopy (ECIS)
Open Access
- 24 April 2020
- journal article
- research article
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (2) , 1-13
Abstract
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 μm electrode width and 50 μm inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubularLLC-PK1cells, representing a normal functional transporting epithelium, and human cervical cancer-derivedHeLacells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring as sensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance in comparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.Keywords
Funding Information
- Österreichische Forschungsförderungsgesellschaft (818050)
- Amt der Tiroler Landesregierung (Transnational Research Projekt i-Scaff)
This publication has 42 references indexed in Scilit:
- Delineation of the Key Aspects in the Regulation of Epithelial Monolayer FormationMolecular and Cellular Biology, 2013
- Real-time label-free monitoring of adipose-derived stem cell differentiation with electric cell-substrate impedance sensingProceedings of the National Academy of Sciences, 2011
- Claudin-2–deficient mice are defective in the leaky and cation-selective paracellular permeability properties of renal proximal tubulesProceedings of the National Academy of Sciences, 2010
- The epithelial polarity program: machineries involved and their hijacking by cancerOncogene, 2008
- Biocompatibility of β-stabilizing elements of titanium alloysBiomaterials, 2004
- Gene expression alterations during HGF-induced dedifferentiation of a renal tubular epithelial cell line (MDCK) using a novel canine DNA microarrayAmerican Journal of Physiology-Renal Physiology, 2004
- Effects of interferon α-2b on barrier function and junctional complexes of renal proximal tubular LLC-PK1 cellsKidney International, 1999
- Cell Division Does Not Increase Transepithelial Permeability of LLC-PK1 Cell SheetsExperimental Cell Research, 1995
- Morphology of the differentiation and maturation of LLC‐PK1 epitheliaJournal of Cellular Physiology, 1990
- Interrelation between Oxygen Consumption and Na-K-ATPase Activity in Rat Renal Proximal Tubule SuspensionKidney and Blood Pressure Research, 1985