Clinical use of oxygen‐enhanced T1mapping MRI of the lung: Reproducibility and impact of closed versus loose fit oxygen delivery system
- 12 December 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (1) , 60-66
Abstract
Purpose: To evaluate the reproducibility of oxygen‐enhanced magnetic resonance imaging (MRI), and the influence of different gas delivery methods, in a clinical environment.Materials and Methods: Twelve healthy volunteers were examined on two visits with an inversion recovery snapshot fast low angle shot sequence on a 1.5 T system. Coronal slices were obtained breathing room air as well as 100% oxygen with a flow rate of 15 L/min. For oxygen delivery a standard nontight face mask and a full closed air‐cushion face mask were used. T1relaxation times and the oxygen transfer function (OTF) were calculated.Results: The mean T1values did not change significantly between the two visits (P > 0.05). The T1values breathing 100% oxygen obtained using the full closed mask were significantly lower (1093 ± 38 msec;P < 0.05) compared to the standard mask (1157 ± 52 msec). Accordingly, the OTF was significantly higher for the full closed mask (P < 0.05). The OTF changed significantly on the second visit using the standard mask (P < 0.05). The full closed mask showed lower interindividual variation for both the T1values (3.5% vs. 4.5%) as well as the OTF (12.4% vs. 22.0%) and no difference of the OTF on the second visit (P > 0.05).Conclusion: Oxygen‐enhanced T1mapping MRI produces reproducible data when using a full closed face mask.J. Magn. Reson. Imaging 2015;41:60–66.©2013 Wiley Periodicals, Inc.Keywords
This publication has 24 references indexed in Scilit:
- MRI of the lung (1/3): methodsInsights into Imaging, 2012
- Vertical distribution of specific ventilation in normal supine humans measured by oxygen-enhanced proton MRIJournal of Applied Physiology, 2010
- Analysis of Signal Dynamics in Oxygen-Enhanced Magnetic Resonance ImagingInvestigative Radiology, 2010
- Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brainMedical Image Analysis, 2008
- T1 mapping of the entire lung parenchyma: Influence of respiratory phase and correlation to lung function test results in patients with diffuse lung diseaseMagnetic Resonance in Medicine, 2007
- Measurement of longitudinal (T1) relaxation in the human lung at 3.0 Tesla with tissue‐based and regional gradient analysesJournal of Magnetic Resonance Imaging, 2007
- T1 mapping of the entire lung parenchyma: Influence of the respiratory phase in healthy individualsJournal of Magnetic Resonance Imaging, 2005
- Imaging lung function using rapid dynamic acquisition of T 1-maps during oxygen enhancementMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- Influence of oxygen flow rate on signal and T1 changes in oxygen‐enhanced ventilation imagingJournal of Magnetic Resonance Imaging, 2002
- Quantification of T1 values by SNAPSHOT-FLASH NMR imagingJournal of Magnetic Resonance (1969), 1992