Optimization of a Passive Solar Heating System for Rural Household Toilets in Cold Regions Using TRNSYS
Open Access
- 16 December 2025
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 17 (24) , 11269
Abstract
To address the poor thermal insulation and freeze resistance of rural outdoor toilets in cold regions—key obstacles to achieving the UN Sustainable Development Goal (SDG) 6.2 and popularizing rural sanitary toilets—this study fills the literature gap of insufficient research on passive solar heating systems tailored for rural toilets in cold climates. Using TRNSYS simulation, Plackett–Burman key factor screening, single-factor experiments, and Box–Behnken response surface methodology, we optimized the system with building envelope thermal parameters and Beijing’s typical meteorological year data as inputs, taking January’s average indoor temperature as the core evaluation index. Results indicated six parameters (solar wall area, air cavity thickness, vent area ratio, vent spacing, exterior wall insulation thickness, and heat-gain window-to-wall ratio) significantly influence indoor temperature (p < 0.05). The optimal configuration was as follows: solar wall area 3.45 m2, window-to-wall ratio 30%, exterior wall insulation thickness 200 mm, vent spacing 1800 mm, air cavity thickness 43 mm, and vent area ratio 5.7%. Post-optimization, the average temperature during the heating season reached 10.81 °C (79.5% higher than baseline), with January’s average, maximum, and minimum temperatures at 7.95 °C, 20.47 °C, and −1.42 °C, respectively. This solution effectively prevents freezing of flushing fixtures due to prolonged low temperatures, providing scientific support for the application of passive rural toilets in China’s cold regions.Keywords
Funding Information
- Institute of Agricultural Planning and Engineering, Ministry of Agriculture and Rural Affairs (QX202424)
- Carbon Emission Assessment of Typical Sanitation Systems in Rural China (QD202419)
- Corps Agricultural CG Project (NYHXGG-2023AA605-02)
This publication has 5 references indexed in Scilit:
- Evaluating the feasibility and challenges of using passive solar systems for achieving thermal comfort in African countries: a reviewInternational Journal of Building Pathology and Adaptation, 2025
- Application of Ventilated Solar Façades to enhance the energy efficiency of buildings: A comprehensive reviewEnergy Reports, 2025
- Evaluation of energy-saving retrofits for sunspace of rural residential buildings based on orthogonal experiment and entropy weight methodEnergy for Sustainable Development, 2022
- Net-zero energy retrofit of rural house in severe cold region based on passive insulation and BAPV technologyJournal of Cleaner Production, 2022
- Energy-Saving Retrofits of Prefabricated House Roof in Severe Cold AreaSSRN Electronic Journal, 2022