Repeatability and accuracy of applanation resonance tonometry in healthy subjects and patients with glaucoma
- 10 July 2013
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 92 (1) , e66-e73
Abstract
To evaluate the repeatability and accuracy of the applanation resonance tonometer (ART) used in the automatic servo-controlled version, and to evaluate the influence of central corneal thickness (CCT) on the ART intraocular pressure (IOP) measurements. This prospective, randomized, single-centre study included one eye of 153 subjects (35 healthy volunteers and 118 patients with glaucoma). All participants underwent ultrasonic CCT measurement, followed by IOP evaluation with Goldmann applanation tonometer (GAT) and ART in random order. A single operator measured the IOP with each tonometer three times. Intra-examiner variability was evaluated using the coefficient of variation (CoV), intraclass correlation coefficient (ICC) and test-retest differences. Intermethod agreement was assessed using the Bland-Altman method. Linear regression analysis was used to evaluate the relationship between IOP measurements and CCT. The mean IOP was 17.7 ± 4.4 mmHg with GAT and 20.6 ± 5.3 mmHg with ART (p < 0.001). CoV and ICC were, respectively, 5 ± 3% and 0.99 for GAT, and 8 ± 4% and 0.96 for ART (intermethods differences, p = 0.001). The ART test-retest differences significantly increased with increasing mean IOP (p = 0.003). The mean IOP difference (ART minus GAT) was 3.0 ± 4.0 mmHg, which increased with increasing mean IOP (p < 0.001). Both GAT IOP and ART IOP readings were significantly directly related to the CCT values (p = 0.03 and p = 0.004, respectively; intermethods difference, p = 0.32). The ART intra-examiner repeatability was excellent, although significantly lower than that of GAT, and decreased at higher IOP levels. ART significantly overestimated GAT IOP measurements, especially at higher IOP range. Both GAT and ART appeared similarly influenced by CCT value.Keywords
This publication has 44 references indexed in Scilit:
- Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer TonometryJournal of Glaucoma, 2013
- Intraocular Pressure Measurement Precision with the Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer TonometersOphthalmology, 2010
- Pascal, ICare and Goldmann applanation tonometry – a comparative studyActa Ophthalmologica, 2008
- Clinical Evaluation of Applanation Resonance TonometryJournal of Glaucoma, 2007
- Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucomaActa Ophthalmologica Scandinavica, 2006
- Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thicknessBritish Journal of Ophthalmology, 2006
- Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-basedin vitroporcine eye modelJournal of Medical Engineering & Technology, 2006
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Über ApplanationstonometrieOphthalmologica, 1957