The design of an optical fiber pressure transducer for use in the upper airways
Authors:
- P.D. GoodyerPGP.D. Goodyer
- J.C. FothergillJFJ.C. Fothergill
- N.B. JonesNJN.B. Jones
- C.D. HanningCHC.D. Hanning
- 1 June 1996
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 43 (6) , 600-606
Abstract
The development of an optical fiber transducer for use in biomedical applications has been presented. The design was targeted for use in the upper airways of patients with sleep disorders stemming from partial or total occlusion of the airway. The transducer's preliminary specification was suited for that of upper airway manometry: a resolution of 10 Pa over the range +/- 5 kPa, a single transducer being less than 0.94 mm in diameter. Amplitude modulated optical fiber sensors are susceptible to loss due to bending of the fiber core and cladding. The design of the transducer uses a series of three optical fibers, one emitting and two receiving, the combination of the two receiving optical fibers is used to reduce effects of light loss: a bend radius of 50 mm is typical for the insertion into the naso-pharynx. The transducer transduction element is a silicone gel coated with reflective titanium dioxide, the meniscus deforms under pressure and modulates the intensity of light reflected back into the receiving optical fibers. The main disadvantage of optical fiber pressure transducers is their susceptibility to temperature drift. Temperature in the airway rarely changes more than 17 degrees C. The frequency of breathing and the high thermal mass of the catheter means that temperature drift in this application is not significant, and will cause an insignificant error of 12 Pa. The transducer is inexpensive to produce, and may be deemed disposable: approximately $20 in material costs (using current manufacturing techniques this can be halved). The system has the added advantage of being electrically, magnetically, and chemically passive. The potential for miniaturization is limited only by the mechanical strength of the optical fibers as mechanical problems associated with fragile elastic membranes do not apply.4170Keywords
This publication has 9 references indexed in Scilit:
- Historical review of microbend fiber-optic sensorsJournal of Lightwave Technology, 1995
- Infant sleeping position and inspiratory pressures in the upper airways and oesophagus.Archives of Disease in Childhood, 1994
- Continuous pressure measurements in the pharynx and esophagus during sleep in patients with obstructive sleep apnea syndromeThe Laryngoscope, 1992
- GaAs-based fiber-optic pressure sensorIEEE Transactions on Instrumentation and Measurement, 1992
- Fiber-optic diaphragm pressure sensor with automatic intensity compensationSensors and Actuators A: Physical, 1991
- Development of medical pressure and temperature sensors employing optical spectrum modulationIEEE Transactions on Biomedical Engineering, 1991
- Intrinsic fiber-optic sensorsIEEE Transactions on Industry Applications, 1991
- Alteration of airway wall temperature during different inhalation proceduresJournal of Aerosol Science, 1990
- Optoelectronic transducer for intravascular measurements of pressure variationsMedical & Biological Engineering & Computing, 1969