A Novel Wind Farm Control Strategy to Mitigate Voltage Dip Induced Frequency Excursion
- 31 May 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 10 (2) , 637-645
Abstract
In this paper, a novel wind farm control strategy is proposed to mitigate voltage dip induced frequency excursion in wind integrated power systems. In the proposed control strategy, conventional fixed reactive/active current injection priority is replaced by an optimum adaptive priority based reactive and active current injection. The control problem is formulated as binary integer optimization problem, which simultaneously minimizes active power shortfall from wind generation during fault and complies with grid code requirements. Detailed wind farm model and wake effect are taken into consideration to achieve realistic response from the wind farm, while IEC 61400-27-1 wind turbine generator model is adopted for wind turbine modelling. Dynamic model of the test system has been developed in DIgSILENT PowerFactory, while the static model is also developed in MATLAB, and co-simulation platform has been used to test and validate the proposed control strategy.Keywords
Funding Information
- Department of Science and Technology (ECR/2016/001465)
This publication has 24 references indexed in Scilit:
- The Effect of FRT Behavior of VSC-HVDC-Connected Offshore Wind Power Plants on AC/DC System DynamicsIEEE Transactions on Power Delivery, 2015
- Dynamic Reactive Power Compensation of Large-Scale Wind Integrated Power SystemIEEE Transactions on Power Systems, 2014
- Adaptive deloading of stand-alone wind farm for primary frequency controlEnergy Systems, 2014
- Enhanced reactive power allocation of full converter wind generation system2014
- Fault Response of a DFIG-based Offshore Wind Power Plant Taking into Account the Wake EffectJournal of Electrical Engineering & Technology, 2014
- Studying the Maximum Instantaneous Non-Synchronous Generation in an Island System—Frequency Stability Challenges in IrelandIEEE Transactions on Power Systems, 2014
- Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability SolutionIEEE Transactions on Power Systems, 2014
- Wake effect in wind farm performance: Steady-state and dynamic behaviorRenewable Energy, 2012
- Active current control in wind power plants during grid faultsWind Energy, 2010
- Optimum Generation Control in Wind Parks When Carrying Out System Operator RequestsIEEE Transactions on Power Systems, 2006