Black-out test vs. UV camera for corona inspection of HV motor stator endwindings
Authors:
- 1 January 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
As part of a factory acceptance test program for high voltage motors, end users sometimes specify a black-out test. This is a traditional offline inspection where the stator is placed in complete darkness, each phase is energized to 115% of rated line-to-neutral voltage, and both ends of the stator are observed to determine the presence, location and severity of endwinding surface partial discharges (PD). The setup for the test may be complex and risky due to the need for observers to be standing in darkness close to the energized parts of the stator. The test results are qualitative and strongly depend on the observer's eyesight and individual perception. A safer and more accurate alternative is to use an ultraviolet (UV) camera or viewer. The observed PD activity may be observed in ambient lighting, recorded, and quantified through simultaneous offline PD measurements. This paper describes the two inspection techniques, and presents experimental validation of the UV corona camera inspection method as a suitable replacement for a black-out test. Sample 13.8-kV coils were wound in a fixture simulating their relationship in a stator winding, and subjected to high-potential tests while observed under black-out conditions and with a UV corona camera in ambient lighting. The stator windings from two high voltage compressor motors were inspected using the same camera. Recorded images of the observed discharges and measured PD activity in the sample coils and stator winding were used to compare the evaluation by each test method.Keywords
This publication has 8 references indexed in Scilit:
- Choosing diagnostic tests to monitor stator insulation in critical motors2012
- The principles of obtaining stable semiconducting compositions and reliable anti-corona designs for high voltage windings2009
- Effectiveness of Stress Grading Coatings on Form Wound Stator Coil Groundwall Insulation Under Fast Rise Time Pulse VoltagesIEEE Transactions on Energy Conversion, 2005
- Understanding the need for anti-corona materials in high voltage rotating machines2002
- Anti-corona protection of the high voltage stator windings and semi-conductive materials for its realization2002
- Electrical aging and electroluminescence in epoxy under repetitive voltage surgesIEEE Transactions on Electrical Insulation, 1992
- Investigation of the effect of repetitive voltage surges on epoxy insulationIEEE Transactions on Energy Conversion, 1992
- Insulation enhancement with heat-shrinkable components. III. Shielded power cableIEEE Electrical Insulation Magazine, 1991