Simulation and exergy-method analysis of an industrial refrigeration cycle used in NGL recovery units
Authors:
- 8 September 2006
- journal article
- research article
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 30 (15) , 1336-1351
Abstract
The behaviour of an industrial refrigeration cycle with refrigerant propane has been investigated by the exergy method. An natural gas liquid recovery unit with its refrigeration cycle has been simulated to prepare the exergy analysis. Using a typical actual work input value; the exergetic efficiency of the refrigeration cycle is determined to be 26.51% indicating a great potential for improvements. The obtained simulation results reveal that the exergetic efficiencies of the air cooler(s) and chilling sections get the lowest rank among the other compartments of refrigeration cycle. Refrigeration calculations have been carried out through the analysis of T–S and P–H diagrams where coefficient of performance (COP) was obtained as 1.8. The novelty of this article include the suggestions for increasing efficiencies, along with the discussion about the reasons for deviation from ideal cycles and also the effect and sensitivity analysis of pressure drops on the coefficient of performance of the cycle. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 11 references indexed in Scilit:
- Exergy analysis of a two-stage refrigeration cycle using two natural substitutes of HCFC22International Journal of Exergy, 2005
- Using multi-stack and variable-speed-drive systems to reduce laboratory exhaust fan energyInternational Journal of Energy Research, 2004
- Exergy and exergoeconomic analysis of a crude oil combined distillation unitEnergy, 2004
- Exergy losses in refrigerating systems. A study for performance comparisons in compressor and condenserInternational Journal of Energy Research, 2003
- Exergy analysis of multistage cascade refrigeration cycle used for natural gas liquefactionInternational Journal of Energy Research, 2002
- Exergy analysis of vapor compression refrigeration systemsExergy, An International Journal, 2002
- Exergy analysis: an absorption refrigerator using lithium bromide and water as the working fluidsApplied Thermal Engineering, 2000
- Exergy analysis of waste emissionsInternational Journal of Energy Research, 1999
- Exergy-method analysis of a two-stage vapour-compression refrigeration-plants performanceApplied Energy, 1998
- Theory of the exergetic costEnergy, 1993