A Robust Beat-to-Beat Artifact Detection Algorithm for Pulse Wave
Open Access
- 11 November 2020
- journal article
- research article
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-8
Abstract
With the rise of the concept of smart cities and healthcare, artificial intelligence helps people pay increasing attention to the health of themselves. People can wear a variety of wearable devices to monitor their physiological conditions. The pulse wave is a kind of physiological signal which is widely applied in the physiological monitoring system. However, the pulse wave is susceptible to artifacts, which prevents its popularization. In this work, we propose a novel beat-to-beat artifact detection algorithm, which performs pulse wave segmentation based on wavelet transform and then detects artifacts beat by beat based on the decision list. We verified our method on data acquired from different databases and compared with experts’ annotations. The segmentation algorithm achieved an accuracy of 96.13%. When it is applied to detect main peaks, the performance achieved an accuracy of 99.11%. After the previous segmentation algorithm, the artifact detection algorithm can detect beat-to-beat pulse waves and artifacts with an accuracy of 98.11%. The result indicated that the proposed method is robust for pulse waves of different patterns and could effectively detect the artifact without the complex algorithm. In summary, our proposed algorithm is capable of annotating pulse waves of various patterns and determining pulse wave quality. Since our method is developed and evaluated on the transmission-mode PPG data, it is more suitable for the devices and applications inside the hospitals instead of reflectance-mode PPG.Keywords
Funding Information
- National Natural Science Foundation of China (61071004, 18441900900, 2017SHZDZX01, 19DZ2250800)
- Shanghai Science and Technology Support Project (61071004, 18441900900, 2017SHZDZX01, 19DZ2250800)
- Shanghai Municipal Science and Technology Major Project (61071004, 18441900900, 2017SHZDZX01, 19DZ2250800)
- Project of Shanghai Engineering Research Center (61071004, 18441900900, 2017SHZDZX01, 19DZ2250800)
This publication has 22 references indexed in Scilit:
- Primary study for detection of arterial blood pressure waveform components2015
- Noise cleaning and Gaussian modeling of smart phone photoplethysmogram to improve blood pressure estimation2015
- Artifacts in wearable photoplethysmographs during daily life motions and their reduction with least mean square based active noise cancellation methodComputers in Biology and Medicine, 2012
- Multiparameter Intelligent Monitoring in Intensive Care II: A public-access intensive care unit database*Critical Care Medicine, 2011
- Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometryPhysiological Measurement, 2010
- An Automatic Beat Detection Algorithm for Pressure SignalsIEEE Transactions on Biomedical Engineering, 2005
- Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers2005
- Forward and Backward Running Waves in the Arteries: Analysis Using the Method of CharacteristicsJournal of Biomechanical Engineering, 1990
- Estimation of arterial pulse wave velocities in the frequency domain: method and clinical considerationsMedical & Biological Engineering & Computing, 1986
- A critical review of the systolic time intervals.Circulation, 1977