Surgeon-designed patient-specific instrumentation improves glenoid component screw placement for reverse total shoulder arthroplasty in a population with small glenoid dimensions
Open Access
- 10 February 2023
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (5) , 1267-1275
Abstract
Purpose: Glenoid component loosening is a potential complication of reverse total shoulder arthroplasty (rTSA), occurring in part due to lack of adequate screw purchase in quality scapular bone stock. This study was to determine the efficacy of a surgeon-designed, 3D-printed patient-specific instrumentation (PSI) compared to conventional instrumentation (CI) in achieving longer superior and inferior screw lengths for glenoid component fixation. Methods: A multi-centre retrospective analysis of patients who underwent rTSA between 2015 and 2020. Lengths of the superior and inferior locking screws inserted for fixation of the glenoid baseplate component were recorded and compared according to whether patients received PSI or CI. Secondary outcomes included operative duration and incidence of complications requiring revision surgery. Results: Seventy-three patients (31 PSI vs. 42 CI) were analysed. Average glenoid diameter was 24.5 mm (SD: 3.1) and 81% of patients had smaller glenoid dimensions compared to the baseplate itself. PSI produced significantly longer superior (44.7 vs. 30.7 mm; P < 0.001) and inferior (43.0 vs. 31 mm; P < 0.001) mean screw lengths, as compared to CI. A greater proportion of maximal screw lengths for the given rTSA construct (48 mm) were observed in the PSI group (71.9% vs. 11.9% superior, 59.4% vs. 11.9% inferior). Operative duration was not statistically significantly different between the PSI and CI groups (150 min vs. 169 min, respectively; P = 0.229). No patients had radiographic loosening of the glenoid component with an average of 2-year follow-up. Conclusion: PSI facilitates longer superior and inferior screw placement in the fixation of the glenoid component for rTSA. With sufficient training, PSI can be designed and implemented by surgeons themselves.Keywords
This publication has 27 references indexed in Scilit:
- Reverse shoulder arthroplasty versus hemiarthroplasty for acute proximal humeral fractures. A blinded, randomized, controlled, prospective studyJournal of Shoulder and Elbow Surgery, 2014
- Comparison of Hemiarthroplasty and Reverse Shoulder Arthroplasty for the Treatment of Proximal Humeral Fractures in Elderly PatientsJournal of Bone and Joint Surgery, 2013
- Early clinical results of reverse total shoulder arthroplasty in the Korean populationJournal of Shoulder and Elbow Surgery, 2013
- Reverse shoulder arthroplasty glenoid fixation: is there a benefit in using four instead of two screws?Journal of Shoulder and Elbow Surgery, 2013
- Functional outcomes of reverse shoulder arthroplasty compared with hemiarthroplasty for acute proximal humeral fracturesJournal of Shoulder and Elbow Surgery, 2013
- Optimal screw placement for base plate fixation in reverse total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2011
- Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical studyJournal of Shoulder and Elbow Surgery, 2009
- Optimizing glenosphere position and fixation in reverse shoulder arthroplasty, Part Two: The three-column conceptJournal of Shoulder and Elbow Surgery, 2008
- Factors affecting fixation of the glenoid component of a reverse total shoulder prothesisJournal of Shoulder and Elbow Surgery, 2008
- Locations for screw fixation beyond the glenoid vault for fixation of glenoid implants into the scapula: An anatomic studyJournal of Shoulder and Elbow Surgery, 2007