Partial Discharge Features for Power Electronic Transformers Under High-Frequency Pulse Voltage
- 8 February 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 49 (2) , 845-853
Abstract
Power electronic transformers (PETs) are becoming popular in the modern dc distribution grid due to their high efficiency and flexibility. To increase the power density of PETs, high-switching frequency would be adopted for the power switches. However, this may eventually increase the risk of partial discharge (PD) as the internal insulation space is reduced. In order to investigate PD characteristics in PETs under high-frequency pulse voltage, an experimental platform was set up in the laboratory, in which a twisted pair of wires model was used to test the insulation failure between windings in PETs. The PD behaviors were thoroughly investigated in the frequency range of 50 Hz to 20 kHz by time-resolved PD (TRPD). The results reveal that at high frequency, both the initial discharge voltage and discharge repetition would increase, while the PD amplitude decreases. Moreover, the PD pulses mainly occur at the field strength inversion of the rising and falling edges, the discharge time width tends to increase at high frequency. By analyzing the discharge model under pulse voltage, the discharge amplitude decrease and discharge times increase due to the difference of charge accumulation field intensity and effective discharge time at different frequencies. Under high-frequency voltage, the number of PD and the proportion of discharge time is much higher than 50 Hz, which may be the main reason for high-frequency insulation failure prematurely. According to the insulation life model based on the total discharge amplitude, the insulation life of 20 kHz is slightly higher than 10 kHz. When designing HFT, 20 kHz should be elected as operation frequency rather than 10 kHz.Keywords
Funding Information
- Jiangsu Planned Projects for Postdoctoral Research Funds
- China Postdoctoral Science Foundation (2019M661828)
This publication has 22 references indexed in Scilit:
- Optimal Design and Implementation of High-Voltage High-Power Silicon Steel Core Medium-Frequency TransformerIEEE Transactions on Industrial Electronics, 2017
- Solid-State Transformers: On the Origins and Evolution of Key ConceptsIEEE Industrial Electronics Magazine, 2016
- Medium-Voltage Solid-State Transformer: Technology for a Smarter and Resilient GridIEEE Industrial Electronics Magazine, 2016
- Lifespan and aging modeling methods for insulation systems in electrical machines: A survey2015
- Partial Discharge Phenomenology and Induced Aging Behavior in Rotating Machines Controlled by Power ElectronicsIEEE Transactions on Industrial Electronics, 2014
- Effects of voltages with high-frequency contents on the transformer insulation properties2013
- Effect of supply voltage frequency on testing of insulation systemIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveformsIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- PD Recurrence in Cavities at Different Energizing MethodsIEEE Transactions on Instrumentation and Measurement, 2004
- The effect of voltage frequency on partial discharge activity2003