Abstract
The paper presents the analysis of using tuned mass damper system for reducing the response of structure subjected to lateral force, such as earthquake action. The assumed steel eight-story steel frame building is examined. The tuned mass damper system is modeled as 2 joint link in SAP2000, attached to top story of the building. The effect of tuned mass damper system for building under seismic excitation was evaluated by the results of maximum displacement and acceleration of the building. A sensitivity study was also performed to compare the structural response with different mass ratios. From the calculated results, discussions and conclusions are presented.Keywords
This publication has 8 references indexed in Scilit:
- Vibration Control for Building Structures2020
- Research developments in vibration control of structures using passive tuned mass dampersAnnual Reviews in Control, 2017
- Tall Building Design2016
- Hybrid nonlinear control of a tall tower with a pendulum absorberSTRUCTURAL ENGINEERING AND MECHANICS, 2013
- Optimal design theories and applications of tuned mass dampersEngineering Structures, 2006
- Optimum tuned‐mass dampers for minimizing steady‐state response of support‐excited and damped systemsEarthquake Engineering & Structural Dynamics, 1993
- Vibration control of tall buildingsEngineering Structures, 1983
- Tuned Mass Dampers for BuildingsJournal of the Structural Division, 1977