Transient Flow Behavior Caused by Long Foundation Pit Dewatering in a Leaky Confined Aquifer
Open Access
Abstract
Groundwater drawdown during dewatering of long excavations is influenced by cutoff walls and leakage from adjacent aquitards, yet their coupled transient effects are not fully represented by existing semi-analytical models. We develop a two-dimensional semi-analytical solution for constant-rate pumping in a leaky confined aquifer bounded by a partially penetrating cutoff wall. The formulation accounts for aquifer anisotropy, aquitard storage and vertical leakage, partial penetration of the pumping well, and groundwater exchange beneath the wall. The governing equations are solved using Laplace transformation and separation of variables; numerical Laplace inversion yields time-dependent drawdown. Model predictions are compared with finite-element results, a published non-leaky solution, and pumping test observations from a long excavation in Shanghai. The parameter analyses indicate that deeper wall penetration increases in-pit drawdown while slightly reducing drawdown outside the wall. Lower vertical-to-horizontal hydraulic conductivity ratios intensify the in-pit response. Reducing aquitard hydraulic conductivity or increasing its thickness limits leakage recharge and raises drawdown in both zones, whereas aquitard specific storage primarily influences the timing of the transient response. The results demonstrate that wall geometry and aquitard properties jointly control drawdown magnitude and evolution, and that the proposed solution can support preliminary assessment of dewatering schemes where two-dimensional flow is a reasonable approximation.Keywords
Funding Information
- National Natural Science Foundation of China (41702336)
- Wuhan Municipal Construction Group Co., Ltd. (wszky202214)
This publication has 44 references indexed in Scilit:
- Transient flow induced by pumping in an anisotropic confined aquifer with a waterproof curtain during excavation dewateringComputers and Geotechnics, 2024
- Two‐region flow caused by pumping at a partial penetration well in a leaky confined aquiferInternational Journal for Numerical and Analytical Methods in Geomechanics, 2023
- Behaviours of wall and soil during pre-excavation dewatering under different foundation pit widthsComputers and Geotechnics, 2019
- Experimental investigation on the blocking of groundwater seepage from a waterproof curtain during pumped dewatering in an excavationHydrogeology Journal, 2019
- Calculation of head difference at two sides of a cut-off barrier during excavation dewateringComputers and Geotechnics, 2017
- Semi-analytical solution to pumping test data with barrier, wellbore storage, and partial penetration effectsEngineering Geology, 2017
- Evaluation of the blocking effect of retaining walls on groundwater seepage in aquifers with different insertion depthsEngineering Geology, 2014
- Dewatering of a deep excavation undertaken in a layered soilEngineering Geology, 2014
- Controlling subsidence caused by de-watering in a deep foundation pitBulletin of Engineering Geology and the Environment, 2012
- Hydraulic characterization of diaphragm walls for cut and cover tunnellingEngineering Geology, 2012