Evaluation of CGMS ® During Rapid Blood Glucose Changes in Patients with Type 1 Diabetes
- 1 April 2006
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 8 (2) , 146-155
Abstract
Background:CGMS® (Medtronic Minimed, Duesseldorf, Germany) allows continuous glucose monitoring. Recent studies with invasive monitoring techniques revealed discrepancies in blood glucose measurements obtained from different anatomical sites compared with those from the fingertip. The aim of this study was to investigate the CGMS and a device for alternative site testing (AST) during dynamic blood glucose changes and to compare these results with fingertip measurements. Methods: Twelve patients with type 1 diabetes (seven women, five men; age, 33.3 ± 8.7 years) received a 75-g oral glucose load. Insulin was applied intravenously (rapid glucose decline) or subcutaneously (moderate glucose decline) in a dosage between 3 to 18 units 2 h later in a randomized sequence on two different days. For continuous glucose measurements the CGMS standard sensor was inserted into the lower abdominal subcutis. Glucose measurements were obtained from the forearm using a minimally invasive technique (AST). CGMS and AST measurements were compared with glucose measurements obtained from the fingertip using a standard glucose oxidase method. Results: No significant difference could be observed among all three methods during increasing glucose levels. Insulin-induced blood glucose decline resulted in a significant time lag in the time course of blood glucose measurements obtained by AST compared with those obtained from the fingertip (P < 0.05, respectively). No significant difference could be observed between CGMS and fingertip measurements. Error grid analysis revealed 100% during rapid glucose fall and 98.5% during modest glucose fall of CGMS measurements within the clinically acceptable zones A and B. Conclusions: Continuous glucose measurements using CGMS provide reliable glucose measurements even in the case of dynamic blood glucose changes.Keywords
This publication has 30 references indexed in Scilit:
- Glucose Monitoring at the Thenar: Evaluation of Upper Dermal Blood Glucose Kinetics During Rapid Systemic Blood Glucose ChangesHormone and Metabolic Research, 2002
- Vacuum-Assisted Lancing of the Forearm: An Effective and Less Painful Approach to Blood Glucose MonitoringDiabetes Technology & Therapeutics, 2000
- Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home UseDiabetes Technology & Therapeutics, 2000
- Hypoglycemia in the Diabetes Control and Complications TrialDiabetes, 1997
- Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life ConditionsDiabetes Care, 1997
- Nitric oxide release accounts for insulin's vascular effects in humans.Journal of Clinical Investigation, 1994
- Self-Monitoring of Blood GlucoseDiabetes Care, 1994
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Microvascular blood flow, volume, and velocity measured by laser Doppler techniques in IDDMDiabetes, 1989
- Blood flow in the foot, polyneuropathy and foot ulceration in diabetes mellitusDiabetologia, 1987