Quantifying CD4 receptor protein in two human CD4+ lymphocyte preparations for quantitative flow cytometry
Open Access
- 11 December 2014
- journal article
- research article
- Published by Springer Nature in Clinical Proteomics
- Vol. 11 (1) , 1-10
Abstract
In our previous study that characterized different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available lyophilized PBMC (Cyto-Trol™) preparation fulfilled a set of criteria for serving as biological calibrators for quantitative flow cytometry. However, the biomarker CD4 protein expression level measured for T helper cells from Cyto-Trol was about 16% lower than those for cryopreserved PBMC and fresh whole blood using flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized lyophilized control cells. Targeted multiple reaction monitoring (MRM) mass spectrometry (MS) is used to quantify the copy number of CD4 receptor protein per CD4+ lymphocyte. Scanning electron microscopy (SEM) is utilized to assist searching the underlying reasons for the observed difference in CD4 receptor copy number per cell determined by MRM MS and CD4 expression measured previously by flow cytometry. The copy number of CD4 receptor proteins on the surface of the CD4+ lymphocyte in cryopreserved PBMCs and in lyophilized control cells is determined to be (1.45 ± 0.09) × 105 and (0.85 ± 0.11) × 105, respectively, averaged over four signature peptides using MRM MS. In comparison with cryopreserved PBMCs, there are more variations in the CD4 copy number in lyophilized control cells determined based on each signature peptide. SEM images of CD4+ lymphocytes from lyophilized control cells are very different when compared to the CD4+ T cells from whole blood and cryopreserved PBMC. Because of the lyophilization process applied to Cyto-Trol control cells, a lower CD4 density value, defined as the copy number of CD4 receptors per CD4+ lymphocyte, averaged over three different production lots is most likely explained by the loss of the CD4 receptors on damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the nearly 50% lower CD4 receptor density value for cryopreserved PBMC determined from flow cytometry compared to the value obtained from MRM MS.Keywords
This publication has 21 references indexed in Scilit:
- Quantifying the Cluster of Differentiation 4 Receptor Density on Human T Lymphocytes Using Multiple Reaction Monitoring Mass SpectrometryAnalytical Chemistry, 2013
- Anti-CD4 Monoclonal Antibody Ibalizumab Exhibits Breadth and Potency Against HIV-1, With Natural Resistance Mediated by the Loss of a V5 Glycan in EnvelopeJAIDS Journal of Acquired Immune Deficiency Syndromes, 2013
- Human CD4+ lymphocytes for antigen quantification: Characterization using conventional flow cytometry and mass cytometryCytometry Part A, 2012
- Toward quantitative fluorescence measurements with multicolor flow cytometryCytometry Part A, 2007
- Differential role of lipid rafts in the functions of CD4+ and CD8+ human T lymphocytes with agingCellular Signalling, 2006
- Lymphocyte microvilli are dynamic, actin-dependent structures that do not require Wiskott-Aldrich syndrome protein (WASp) for their morphologyBlood, 2004
- Localization of CD4 and CCR5 in Living CellsJournal of Virology, 2003
- CCR5, CXCR4, and CD4 Are Clustered and Closely Apposed on Microvilli of Human Macrophages and T CellsJournal of Virology, 2001
- Carbohydrate structures of recombinant soluble human CD4 expressed in Chinese hamster ovary cellsBiochemistry, 1991
- Surface CD4 density remains constant on lymphocytes of HIV-infected patients in the progression of diseaseResearch in Immunology, 1991