Impact of corona on the long-term performance of nonceramic insulators
Authors:
- A. KroeseAKA. Kroese
- 6 February 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 10 (1) , 80-95
Abstract
A majority of nonceramic insulator (NCI) application is under relatively clean conditions where leakage current may be nonexistent. Occurrence of corona for long periods of time on NCI operating under relatively clean conditions is possible due to localized high electric field (E-field) brought about by design and manufacturing deficiencies. Therefore, resistance to corona-induced degradation of NCI housing materials is an important factor that impacts NCI long-term reliability, and is the focal point of this paper. Two sources of corona have been investigated: corona from a metal electrode, and corona from water droplets. Field inspections were performed on 230 and 500 kV insulators to demonstrate the existence of corona even under relatively clean and dry conditions. Three commonly used NCI housing materials, namely high temperature vulcanized (HTV) silicone rubber (SIR), ethylene propylene diene monomer (EPDM) and a blend of EPDM and silicone polymer were evaluated in the laboratory. In addition, housing materials from several insulators removed from the field were analyzed. Data gathered from electrical and physicochemical analyses show that corona induced degradation is dominantly due to a combination of electro-chemical reactions rather than thermal effects.Keywords
This publication has 23 references indexed in Scilit:
- Outdoor HV composite polymeric insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 1999
- Surface discharges on polymeric insulator shed surfacesIEEE Transactions on Dielectrics and Electrical Insulation, 1997
- Streamer radius model and its assessment using two-dimensional modelsIEEE Transactions on Plasma Science, 1996
- History and bibliography of polymeric insulators for outdoor applicationsIEEE Transactions on Power Delivery, 1993
- Measurements of neutral densities and temperatures in negative air coronas using an optical interferometer and a thermocoupleJournal of Physics D: Applied Physics, 1986
- An interferometric measurement of gas temperatures in corona dischargesJournal of Physics D: Applied Physics, 1982
- Michelson interferometer studies of temperature patterns in DC point-to-plane electrical discharges in airJournal of Physics D: Applied Physics, 1980
- Negative d.c. corona study in atmospheric air using Schlieren and interferometric techniquesIEE Proceedings A Physical Science, Measurement and Instrumentation, Management and Education, Reviews, 1980
- Corona discharge and energy transferJournal of Physics D: Applied Physics, 1978
- Ionic Reactions in Corona Discharges of Atmospheric Gases1969